Chapter 3 Test Mode
3-13
AC-4000H Service Manual No. 085-7323-08
3.6
Label Sensor Check
LABEL SENSOR CHECK
Press the [
↓
] key to increment a menu, or enter a desired menu number followed by the [
↓
] key.
kg
MASS
R/kg
R
AMOUNT
.#$'.5'0514%*'%-='06'4?
.#$'.5'0514%*'%-='06'4?
LABEL SENSOR [Output value adjustment]
kg
MASS
R/kg
R
AMOUNT
.#$'.5'0514
.#$'.5'0514
•
[32 ] : Label sensor resistance value
•
[33 ] : Label sensor output value (Label + Baking paper)
•
[140] : Label sensor output value (Baking paper only)
•
At adjustment: Label sensor output value deviation must be 50 or more between the case when a label
exists and when no label exists.
•
Output from the label sensor is displayed with a value after passing through the A/D converter.
•
Adjustment value range: 0 to 255
•
Adjustment method: Adjust the label sensor volume in digital form. Key in “0 to 255” and press the
ENTER key to store.
•
Press the END key to return to the test mode menu screen.