Chapter 3 Test Mode
AC-4000H Service Manual No. 085-7323-08
3-12
PRINT USAGE IN km [Label travel distance display and clear]
kg
MASS
R/kg
R
AMOUNT
24+0675#)'+0MOMO
24+0675#)'+0MOMO
•
This menu is used to check the print total travel distance. It is memorized in 100m unit (0.1km) and
displayed.
•
When resetting the travel distance:
Enter the password “495344”, and press the SIZE key.
RESISTANCE VALUE ADJUSTMENT
[Print density adjustment]
kg
MASS
R/kg
R
AMOUNT
4'5+56#0%'8#.7'#&,
4'5+56#0%'8#.7'#&,
•
Adjust the thermal head print density.
•
Print density adjustment range: 1 (Thin) to 9 (Thick) [Default value = 5]
•
Press the END key to return to the test mode menu screen.