Chapter 3 Test Mode
AC-4000 Service Manual No. 0181B
3-8
I
SETUP CLEAR [E2ROM default]
•
This menu is used when initializing E2ROM to a default value. When this mode is executed, the content
of the E2ROM switch is initialized to default. SRAM clear is executed by pressing the ZERO key twice.
•
When processing is complete, “PASS” is displayed and “OK” buzzer sounds.
•
If an error is detected, “ERR” is displayed and “NG” (No Good) buzzer sounds.
•
Press the END key to return to the hardware test menu screen.
I
TEST DATA SET
•
This menu is used when setting up the machine for the first time (when there is no backup data).
•
In this mode, execute a set of SRAM clear + E2ROM setup + Dummy data creation.
•
The dummy data memorizes 10 PLU data and the store name/address.
•
SRAM clear is executed by pressing the ZERO key twice.
•
When processing is complete, “PASS” is displayed and “OK” buzzer sounds.
•
When an error is detected, “ERR” is displayed and “NG” (No Good) buzzer sounds.