2.11 Scroll Message Display
•
A function to display the registered scroll message. When an item has not been called up, it starts
after five seconds have passed.
•
Display method registration function
(0: No display
1: High-speed scroll
2: Normal scroll
3: Low-speed scroll
4: High-speed blinking
5: Normal blinking
6: Low-speed blinking)
•
Day of the week registration function
(0: Every day 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday 7: Saturday)
•
Display time registration function (Start/stop)
[Example]
09:00 to 13:00
Enter “0913” and press the ENTER key.
•
Maximum number of scroll messages: 9 messages (1 to 9)
•
Maximum number of characters: 96 characters (one byte English code)
2.12 Campaign Function
•
Registered campaign items start to be sold at the registered campaign price when the time reaches
registered campaign time.
•
Maximum number of campaign: 20
•
Maximum number of items for each campaign: 100
•
Discount method
(0: Unit price 1: Special price 2: Amount discount 3: Percent discount 4: Special unit price)
•
Campaign 1 becomes top priority for items registered during the overlapping time.
•
Priority is given from Campaign 1, 2, and 3 to the last 20 if the same item is registered.
That is, priority is given to the campaign 1 even if the same item is registered in campaign 1 and 2
during the overlapping time.
•
Registration of the same item is not supported in one campaign.
•
An error message appears when a label is issued with a registered price in the campaign greater than
the weighing price.