Chapter 3 Test Mode
3-13
AC-4000 Service Manual No. 0181B
3.6 Label Sensor Check
I
LABEL SENSOR CHECK
Press the [
↓
] key to increment a menu, or enter a desired menu number followed by the [
↓
] key.
I
LABEL SENSOR [Output value adjustment]
Note: “LABEL SENSOR” means the Cassette Sensor for AC-4000.
•
[32 ] : Label sensor resistance value
•
[33 ] : Label sensor output value (Label + Baking paper)
•
[140]: Label sensor output value (Baking paper only)
•
At adjustment: Label sensor output value deviation must be 50 or more between the case when a
label exists and when no label exists.
•
Output from the label sensor is displayed with a value after passing through the A/D converter.
•
Adjustment value range: 0 to 255
•
Adjustment method: Adjust the label sensor volume in digital form. Key in “0 to 255” and press the
ENTER key to store.
•
Press the END key, then the MODE key to return to the test mode menu screen.