7. Order guides
CABLE ORDER GUIDE
POWER SUPPLY SIDE
CONNECTOR
CABLE
CODE
CABLE DESCRIPTION
APPLICATIO
N SIDE
CONNECTOR
ORDER CODE
LLL = length in m
(*
SHV
04
HV cable shielded 30kV (HTV-30S-22-2)
open
SHV_1C04-
LLL
Jack plug 3.5mm
CAN to host
D-SUB
female
Z515404
Jack plug 3.5mm
CAN daisy-chain
Jack plug
3.5mm
Z515554
Jack plug 2.5mm (2pol)
VCT Sensor cable
Probe
Z585877
*)
Length building examples: 10cm => 0.1, 2.5m => 2.5, 12m => 012 , 999m => 999
Table 9: Guideline for cable ordering
CONFIGURATION ORDER GUIDE
(item code parts)
NH
06
0
060
P
105
000
02
00
NIM
High
Voltage
Numbers of
channels
Class
V
nom
Polarity
I
nom
(nA)
Option (hex)
HV-Connector
Customized
Version
0 = Standard
2 = HP
three significante
digits *100V
For Examle:
060 = 6000V
p = positive
n = negative
two significante
number
of zeros
For Examle:
105 = 1mA
Sum of the hex
codes (s. table
3)
02 = SHV
00 = none
Table 10: Item code parts for different configurations
8. Appendix
For more information please use the following download links:
This document
https://iseg-hv.com/download/SYSTEM/NHS/iseg_manual_NHS_en_2.0.pdf
iCS (iseg Communication Server)
https://iseg-hv.com/download/?dir=SOFTWARE/iCS
SCPI Programmers-Guide
https://iseg-hv.com/download/SOFTWARE/isegSCPI/SCPI_Programmers-Guide.pdf
CAN EDCP Programmers-Guide
https://iseg-hv.com/download/SOFTWARE/isegEDCP/CAN_EDCP_Programmers-Guide.pdf
isegHAL (Hardware Abstraction Layer)
https://iseg-hv.com/download/SOFTWARE/iCS/doc/isegHAL/index.html
iCSservice-API
https://iseg-hv.com/download/SOFTWARE/iCS/doc/iCSservice/iCSapiWebsocket_Docu.html
https://iseg-hv.com/download/SOFTWARE/iCS/doc/iCSservice/iCSapiWebsocket_Example.html
isegIOC (EPICS Input / Output Controller)
NHS – NIM standard High Voltage Power Supply | Last changed on: 01.10.2018 |