background image

iRBX6GF User’s  Manual 

 

 

UM-iRBX6GF-4.5.1-EN.docx   

 

 

 

 

 

 

 

Pages 29 of 119 

 

 

DEVICE MANAGEMENT

 

To control the iRBX switch, use the following options: 

 

SNMP

—through Mgmt / Inband port 

 

Command Line Interface

RS-232 Serial interface 

 

WebUI—through Mgmt/Inband port 

9.1

 

Configuration Parameters 

The following parameters are preserved across restarts and might be changed through a management 
interface. 

Table 15 – Configuration Parameters 

Parameter 

Description 

Factory Default 

hostname 

Set system's network name 

irbx 

IP Address, 

IP Mask, 

Switch Management  

IP address configuration 

192.16810.1 

255.255.255.0 

Mode 

Switch Redundancy protocol mode: HSR or PRP 

HSR 

SSH 

Secure Shell Protocol 

disabled 

SNMP 

Simple Network Management Protocol 

enabled 

9.2

 

SNMP 

The  iRBX6GF  switch supports MIB which defines the Network Management interfaces for the 

redundancy protocols defined by the IEC 62439 suite  including Simple Network Management 

Protocol (SNMP). SNMP v1 is supported. Standard SNMP browser can be used to manage iRBX6GF 

by using standard IEC-62439-3_Ed2 mib file.  

9.3

 

Command Line Interface Setup 

CLI Management is performed by RS-232 Serial Console (115200, 8, none, 1, none).  Before 

configuring RS-232 serial console, connect the RS-232 port of the switch to your PC. Follow the steps 

below to access the console via a RS-232 serial cable. 

1.

 

Start 

Tara Term

 

VT

 (or other terminal emulator) application. 

 or the app from Command Prompt   

2.

 

Go to 

Setup

 menu and select 

Serial Port

.  

Summary of Contents for iRBX6GF

Page 1: ... 1 EN docx User s Manual iRBX6GF Intelligent 6 Port HSR PRP Ethernet Switch IEC 61850 and IEEE 1613 Compliant http is5com com products irbx6gf Version 4 5 1 Mar 15 2019 2019 iS5 Communications Inc All rights reserved ...

Page 2: ...n this warranty period including shipping costs This warranty does not cover product modifications or repairs done by persons other than iS5 approved personnel and this warranty does not apply to products that are misused abused improperly installed or damaged by accident Refer to the Technical Specifications section for the actual warranty period s of the product s associated with this publicatio...

Page 3: ...2 1 DIN Rail Installation 6 2 2 Mounting on DIN Rail 6 2 3 Panel Mount Installation 7 Mounting on Wall or Panel 7 Hardware Overview 8 3 1 Front Panel 8 3 2 Front Panel LED 9 3 3 Network Ports and Interfaces 9 3 4 Bottom View Panel 10 3 5 Rear Panel 12 3 6 Side Panel 12 Cables 13 4 1 Ethernet Cables 13 Pin Assignments 13 4 2 SFP 14 4 1 1 Supported SFPs 15 4 3 Console Cable 16 SYSLOG GUIDELINES 17 5...

Page 4: ...26 Showing FPGA and firmware Versions 28 Device Management 29 9 1 Configuration Parameters 29 9 2 SNMP 29 9 3 Command Line Interface Setup 29 9 4 Command Line Interface Overview 31 General Context 31 Show Context 31 Configuration Context 31 9 5 General Command Line Interface Syntax 33 Command configure terminal 33 Command exit 39 Command ping 39 Command show 39 9 6 Show Context CLI Syntax 40 show ...

Page 5: ...actory reset command 63 ip command 63 lldp command 64 no command 65 ntp command 65 password command 66 port command 66 ptp command 68 reboot command 69 redundancy commands 69 rstp command 70 save command 75 snmp command 75 ssh command 76 syslog command 79 system 81 vlan command 83 web command 84 WEB management 87 10 1 System 89 System tab 89 Time 89 IP 90 Maintenance 90 Alarm 92 Banner 94 Syslog 9...

Page 6: ...rade Interface 91 Figure 17 Configuration Interface 91 Figure 18 System Reboot Interface 91 Figure 19 Alarm Interface 92 Figure 20 Alarms to generate SNMP trap Interface 93 Figure 21 History of Alarms Interface 93 Figure 22 Banner Interface 94 Figure 23 Syslog Interface 94 Figure 24 Control Syslog Interface 95 Figure 25 Facilities Syslog Interface 95 Figure 26 Search Syslog Interface 96 Figure 27 ...

Page 7: ...onnection 10 Table 5 Port Numbering 13 Table 6 10 100 Base T X Line Pin Assignments 13 Table 7 1000 Base T Line Pin Assignments 13 Table 8 10 100 Base T X MDI MDI X Pin Assignments 14 Table 9 1000 Base T MDI MDI X Pin Assignments 14 Table 10 iRBX SFP compatibility table 15 Table 11 Signals and Pinouts from Console Port RJ 45 to DB 9 Serial Port Adapter 16 Table 12 Examples of Syslog Messages 17 Ta...

Page 8: ...user may be required to take adequate measures Caution LASER This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Caution Service This product contains no user serviceable parts Attempted service by unauthorized personnel shall render...

Page 9: ...EC 62439 3 Clause 5 3 and parallel redundancy protocol PRP IEC 62439 3 Clause 4 3 Both of those standards provide redundant patch with no single point of failure and zero time to recover in case of failure Single network faults in the ring will not result in any frame loss The network is fully operational during maintenance and any device can be disconnected and replaced without breaking network c...

Page 10: ...tion Guide Online AccessedonMay7 2018https docs oracle com cd E39109_01 html E21706 z40037c31419011 html scrolltoc 7 802 1D IEEE Standard for Local and Metropolitan Area Networks Media Access Control MAC Bridges IEEE 2004 8 IEEE 802 1AB Station and Media Access Control Connectivity Discovery LLDP 9 Simple Network Management Protocol Protocol Details https en wikipedia org wiki Simple_Network_Manag...

Page 11: ...P MED LLDP Media Endpoint Discovery LLDPDU LLDP Data Unit MIB Management Information Base NCO Numerically Controlled Oscillator s NTP Network Time Protocol OID Object Identifier PDU Protocol Data Unit PTP Precision Time Protocol P2P Point To Point link RSTP Rapid Spanning Tree Protocol SNMP Simple Network Management Protocol TCP Transmission Control Protocol TLV type length value TTL Time to live ...

Page 12: ... LLDP support WebUI Management 1 5Hardware Specifications Supports 2 Combo ports 2 x 10 100 1000Base T X RJ45 or 2 x 100 1000Base X SFP and 4 x 100 1000 SFP Single HSR PRP Redundancy Box RedBox IEEE 1588 v2 one step command transparent clocks PPS and IRIG B ports future implementation Available with dual power supplies DIN rail or wall mount design Rigid IP 40 galvanized metal housing Compliant wi...

Page 13: ...has a DIN Rail bracket on the rear panel The DIN Rail bracket helps secure the switch on to the DIN Rail 2 2Mounting on DIN Rail Step 1 Tilt the switch and position the top 2 catches of the metal bracket onto the top of the DIN Rail Step 2 Push the bottom of the switch toward the DIN Rail until the bracket snaps in place ...

Page 14: ...ng steps show how to mount the switch on a wall or panel Mounting on Wall or Panel Option 1 Fix mounting brackets to the side of switch using the 4 screws included in the package Option 2 Fix mounting brackets to back of switch using 4 screws included in the package Note To avoid damage to the unit when mounting the panel use the screws provided ...

Page 15: ...t Port 1 x 100Base T X port Console An RS 232 Serial interface use RS 232 with RJ 45 connector to manage switch iRBX6GF 1 100 1000 Base X SFP ports Ports 1 2 2 100 1000 Base X SFP ports Ports 3 4 3 LED for SFP ports link status 4 LED for Combo ports link status 5 Combo ports Ports 5 6 6 Reset button To reset push the button for 3 seconds 7 LED for Alarm When the light on it means failure 8 LED for...

Page 16: ...10 100 1000Base T X Fast Ethernet ports LNK Green On Port link up ACT Green Blinking Data transmitted Full Duplex Amber On Port works under full duplex SFP not shown on picture below LNK Green On Port link up ACT Green On Data transmitted Note LEDs on P1 2 3 4 are always ON No traffic activity indication 3 3Network Ports and Interfaces Port 1 A Port 2 B Port 3 A Port 4 B MGMT Console Port 6 Port 5...

Page 17: ... The Phillips Screw Terminal Block which is located on the bottom of the unit has Phillips screws with compression plates that allow bare wire connections or crimped terminal lugs To ensure secure and reliable connections under severe shock or vibration the use of 6 size ring lugs is recommended The terminal block comes with a safety cover that must be removed before connecting any wires The cover...

Page 18: ...al Connect to the Neutral terminal of Power Supply 2 or backup DC power source 8 FAIL Open Fault Relay 9 FAIL RLY Fault Relay 10 FAIL Close Fault Relay Chassis Ground Connection The iRBX6GF s chassis ground connection which is located next to the terminal block uses a 6 32 screw We recommend terminating the ground connection using a 6 ring lug and a torque setting of 15 in lbs 1 7Nm 100 240VAC rat...

Page 19: ...3 5Rear Panel The components on the rear of the iRBX6GF are as shown below 1 4 Holes for the screws for the wall mount kit 2 DIN Rail mount 3 6Side Panel The components on the side of the iRBX6GF are shown below 1 Holes for the screws 4 for the wall mount kit 1 2 1 ...

Page 20: ...0 m 328ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328ft RJ 45 1000BASE T Cat 5 Cat 5e 100 ohm UTP UTP 100 m 328ft RJ 45 Pin Assignments With 10 100 1000BASE T X cables pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data All pin assignments are as follows Table 6 10 100 Base T X Line Pin Assignments Pin Number Assignment 1 TD 2 TD 3 RD 4 Not used 5 Not used...

Page 21: ... Base T MDI MDI X Pin Assignments Pin Number MDI port MDI X port 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Note and signs represent the polarity of the wires that make up each wire pair 4 2SFP The switch comes with fiber optical ports that can connect to other devices using SFP modules The fiber optical ports are multi mode or s...

Page 22: ... SFP 1Gbps Multimode LC Transceiver 500m 850nm 20C 85C ⱱ ⱱ ⱱ SFP1000 MM 2 SFP 1Gbps Multimode LC Transceiver 2km 1310nm 40C 85C ⱱ ⱱ ⱱ SFP1000 SM 10 SFP 1Gbps Singlemode LC Transceiver 10km 1310nm 40C 85C ⱱ ⱱ ⱱ SFP1000 SM 20 SFP 1Gbps Singlemode LC Transceiver 20km 1310nm 40C 85C ⱱ ⱱ ⱱ SFP1000 SM 40 SFP 1Gbps Singlemode LC Transceiver 40km 1310nm 40C 85C ⱱ ⱱ ⱱ SFP1000 SM 60 this one is on the list ...

Page 23: ...32 cable should be connected to the PC while the other end of the cable with the RJ 45 connector should be connected to the console port of the switch Standard Cisco Serial Cable supplied with iRBX6GF Table 11 Signals and Pinouts from Console Port RJ 45 to DB 9 Serial Port Adapter Console Port PC COM Port RJ 45 DB 9 Pins Signals Pins Signals 1 NC1 2 NC1 3 TXD2 2 RXD3 4 GND4 5 GND4 5 GND4 5 GND4 6 ...

Page 24: ...e implementation 3 If above 95 of the available space has been used the 3 largest logs will be cleared Syslog would report as follows this reporting capability will be available in a future implementation 5 2Examples of Syslog Messages Table 12 Examples of Syslog Messages Facility Action Syslog message system config syslog clear web cdb admin cleared web syslog facility cli The configuration chang...

Page 25: ...r power supply status These parameters are accessible through SNMP CLI and Web UI Critical alarms are viewed through LEDs of the switch An user may selectively assign one or more of the events to monitor If a monitored port changes its link status or if temperature goes above a threshold or power supply goes down an SNMP trap and or syslog message is issued to report that event Alarm configuration...

Page 26: ...Configuration byWEB UI iRBX6GF introduces a global alarm icon in the top right corner of the Web page which represents the status of the alarm Color is changed to red if one or more alarms have been triggered Normal operation of iRBX6GF is identified by green color of the alarm icon For Alarms refer to 10 1 5 Alarm For SNMP traps configuration refer to Sec 10 1 5 1 Alarms to generate SNMP trap For...

Page 27: ...ddress configured Perform the following command irbx config alarm snmp trap manager 192 168 10 10 Stopping rsyslog daemon OK Starting rsyslog daemon OK System warm start after uptime 00 09 40 Welcome to iRBX Switch Copyright c 2017 iS5 Communications All rights reserved irbx login 6 7Fail Safe Relay Test using the following commands login as root cli system fsafe on sh cli system fsafe off sh Tabl...

Page 28: ...d MSTP 5 1 HSR HSR High availability Seamless Redundancy is a redundancy protocol for Ethernet that is standardized as per the IEC 62439 3 Clause 5 3 For more information refer to http en wikipedia org wiki High availability_Seamless_Redundancy HSR and PRP protocols are interoperable Both protocols can be implemented in a network to achieve the desired topology HSR PRP operation is described in HS...

Page 29: ...second eliminating the duplicate frame 7 3HSR PRP Dual RedBox Mode HSR PRP mode also called Dual RedBox mode is used to bridge HSR and PRP networks In this mode two different RedBoxes connect to LAN A and LAN B of the PRP network Two ports connect to the HSR ring and one port connects to one of the two PRP LANs The traffic on the upstream interlink port connecting the RedBox to the PRP network is ...

Page 30: ...I For firmware upgrade via WebUI refer to Section 10 1 4 1 Firmware Upgrade All upgrades are done through TFTP protocol as follows 8 1Connecting Connect management PC with iRBX6GF s Management network port 8 2Installing TFTP Server For Windows download and install from https bitbucket org phjounin tftpd64 Figure 1 TFTP Server Interface ...

Page 31: ...GF User s Manual UM iRBX6GF 4 5 1 EN docx Pages 24 of 119 8 3Configuring TFTP Server Use settings as shown in Figure 2 and Figure 3 Figure 2 TFTP Server Configuration Figure 3 TFTP Server Configuration cont ...

Page 32: ... spots 0 and 1 Option 2 on Menu Edit Active Image allows controlling which image would be loaded by default upon device boot up Option 9 might be used to save a change After reset the selection bar shows which image is selected for automatic load Options 3 5 allow configuring iRBX device IP addressing Options 6 7 allow configuring the TFTP Server address and pinging it to ensure the proper connect...

Page 33: ...hrough u boot menu by following the steps 1 Ensure compliance with the hardware requirements D006 PS0103 FM0615 FB0614 or later 2 Obtain file irbx fpga X YY itb for this manual the most current version is irbx fpga 6 15 itb The iRBX Boor menu 5 34 6 15 appears 3 Identify the FPGA version currently the version is 6 15 and the file is irbx fpga 6 15 itb iRBX configure terminal iRBX config reboot POR...

Page 34: ...rrent itb File 5 Press y to continue Note that the process takes a few minutes Upon successful completion the power cycle is required On the failure you may need to repeat the process or contact Tech Support On success please power cycle and check FPGA version top of u boot menu In the case of failure any reason the desired FPGA version cannot come up the Backup Factory default version may be load...

Page 35: ...irmware Bank 1 iRBX D 4 3 120 20180108 active Type for help config config rstp config rstp disable PORT1 forwarding PORT2 forwarding PORT3 forwarding PORT4 forwarding PORT5 forwarding 70 434000 MGMT port 5 PORT5 M entered disabled state PORT6 forwarding 70 446000 PORT6 state forwarding 120 70 452000 PORT1 normal mode 70 457000 PORT2 normal mode config rstp config rstp snmp config snmp community 1 ...

Page 36: ...e HSR or PRP HSR SSH Secure Shell Protocol disabled SNMP Simple Network Management Protocol enabled 9 2SNMP The iRBX6GF switch supports MIB which defines the Network Management interfaces for the redundancy protocols defined by the IEC 62439 suite including Simple Network Management Protocol SNMP SNMP v1 is supported Standard SNMP browser can be used to manage iRBX6GF by using standard IEC 62439 3...

Page 37: ...ies to 115200 for Baud rate 8 for Data bits none for Parity 1 for Stop bits and none for Flow control Then click OK Figure 8 Tera Term VT Serial port setup Use the following credentials to login as illustrated on the figure below iRBX login admin Password admin Figure 9 Tera Term VT Login Screen Welcome to iS5 Communications Copyright c 2017 iS5 Communications All rights reserved iRBX login ...

Page 38: ...tatus ssh Show ssh status stats Show traffic statistics syslog Show all syslog events system Show system status temperature Show temperature celsius time Show current time timezone Show current timezone uptime Show system uptime version Show firmware version vlans Show vlan configuration and membership iRBX show iRBX configure terminal iRBX config Comments alarm Alarm control do To run exec comman...

Page 39: ...such as IP address gateway etc For example A B C D represents that a MAC address of this format should be provided When the help token cr appears after the help string explaining the operation of the command this means that the command can be executed at that point without any additional parameters iRBX config ip dn dns1 Set DNS server 1 dns2 Set DNS server 2 iRBX config ip iRBX config alarm monit...

Page 40: ...ote To go to the Configuration Context of CLI always use the command configure terminal To complete a command or keyword after entering a partial string press the Tab or just hit Enter alarm command do command exit command Or factory reset command Note Command factory reset requires reboot of the system to apply the configuration settings iRBX configure terminal iRBX config iRBX config alarm iRBX ...

Page 41: ... iRBX config ip iRBX config lldp iRBX config lldp iRBX config no no Negate a command or set its defaults iRBX config no iRBX config ntp iRBX config ntp RBX config password change iRBX config password String username iRBX config password admin Changing password for admin New password password admin iRBX config port 1 iRBX config port1 iRBX config ptp iRBX config ptp ...

Page 42: ...2 168 10 250 7 Ping TFTP Server 8 Pull TFTP Firmware Image 0 9 Edit TFTP Filename irbx D image 4 3 120 itb 10 Edit MAC Address e8 e8 75 80 01 88 11 Edit Unit Serial RBX64917 00006 12 Edit Unit Model iRBX6GF HV HV D 2GSFP 2GSFP 2GCX 13 Save Boot Menu settings 14 Restore Boot Menu defaults U Boot console Press UP DOWN to move ENTER to select Booting kernel from Legacy Image at d2000000 Image Name Li...

Page 43: ...00 brm0 port 6 PORT6 M entered forwarding state 30 321000 brm0 port 5 PORT5 M entered forwarding state 30 322000 brm0 port 5 PORT5 M entered forwarding state 30 530000 8021q adding VLAN 0 to HW filter on device RING0 30 638000 bonding RING0 Enslaving PORT1 as an active interface with a down link 30 681000 bonding RING0 Enslaving PORT2 as an active interface with a down link 30 756000 brm0 port 6 P...

Page 44: ... n All rights reserved n Welcome to iRBX Switch Copyright c 2017 iS5 Communications All rights reserved config system location Earth config system name irbx config system config system vlan 1 config vlan1 ports 1 2 3 4 5 6 config vlan1 config vlan1 ip config ip address 192 168 1 10 24 config ip gateway 192 168 1 1 config ip config ip lldp config lldp enable 2018 04 20T09 03 58 INFO lldpctl LLDP Po...

Page 45: ...l config web acl rule 1 allow config web acl session timeout 30 Syntax error on line etc startup config 48 session timeout 30 Unknown command config web acl config web acl ip config ip address 192 168 10 1 24 config ip management vlan 4 config ip gateway 192 168 10 254 Welcome to iS5 Communications Copyright c 2017 iS5 Communications All rights reserved irbx login iRBX config redundancy iRBX confi...

Page 46: ...All rights reserved iRBX login iRBX ping 198 168 10 11 PING 198 168 10 11 198 168 10 11 56 data bytes 198 168 10 11 ping statistics 5 packets transmitted 0 packets received 100 packet loss iRBX iRBX show show system information iRBX show banner Show banner message config Show running configuration date Show date ip Show IPv4 settings lldp Show lldp status log auth Show authentication log log web S...

Page 47: ...undancy Show redundancy status show redundancy command 11 show rstp Show RSTP status show rstp command 12 show snmp Show SNMP status show snmp command 13 show ssh Show SSH status show ssh command 14 show stats Show ports statistics show stats command 15 show syslog Show all syslog events 16 show system Show system information show system command 17 Show temperature Show temperature Celsius show te...

Page 48: ...4 lldp enable ntp enable server1 1 pool ntp org server2 2 pool ntp org ptp disable one step sync vlan 0 redundancy mode HSR rstp domain 1 enable snmp community 1 public read only enable ssh enable syslog enable system banner Welcome to iRBX Switch n Copyright c 2017 iS5 Communications n All rights reserved n location Earth name irbx vlan 1 ports 1 2 3 4 5 6 web enable session timeout 30 acl iRBX ...

Page 49: ...face MGMT Link encap Ethernet HWaddr E8 E8 75 00 03 12 inet addr 192 168 10 13 Bcast 192 168 10 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 26637 errors 0 dropped 0 overruns 0 frame 0 TX packets 26332 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 0 RX bytes 2380622 2 2 MiB TX bytes 6106378 5 8 MiB Management VLAN iRBX ...

Page 50: ...inventory yes LLDP MED fast start mechanism yes LLDP MED fast start interval none Source MAC for LLDP frames on bond slaves local Port ID TLV subtype for LLDP frames ifname Agent type unknown LLDP Global statistics Summary of stats Transmitted 599 Received 776 Discarded 0 Unrecognized 0 Ageout 0 Inserted 3 Deleted 0 LLDP neighbors Interface PORT5 via LLDP RID 3 Time 0 day 01 44 05 Chassis ChassisI...

Page 51: ...arding PORT6 P6 yes down copper no OOB Mgmt yes down copper iRBX iRBX show ptp Component index 0 name Local NCO device id 0x0090 revision id 0x02 properties 0x1f Time read seconds 1167708462 nanoseconds 990163435 subnsecs 0x0000 clk cycle cnt 0x00000b3dcad934e5 Register content nco subnsec reg 0x00000000 nco nsec reg 0x3b04b1eb nco sec reg 0x00004599d12e nco cccnt reg 0x0b3dcad934e5 nco step subns...

Page 52: ...Bridge Priority 8 Port Link Member Dis bpdu Cost Priority P2P Edge Admin Auto Role State R A B down yes no 0 128 auto no yes disabled discarding PORT3 down yes no 0 128 auto no yes disabled discarding PORT4 down yes no 0 128 auto no yes disabled discarding PORT5 up yes no 0 128 auto no yes root forwarding PORT6 down yes no 0 128 auto no yes disabled discarding iRBX iRBX show snmp status snmpd is r...

Page 53: ...4 r x _ c r c _ e r r o r _ p a c k e t s 0 0 0 0 0 0 0 x 3 1 2 2 r x _ h s r _ p r p _ p a c k e t s 0 0 0 0 0 0 0 x 3 1 2 4 r x _ p r p _ w r o n g _ l a n _ p a c k e t s 0 0 0 0 0 0 0 x 3 1 2 6 r x _ h s r _ p r p _ d u p l i c a t e _ p a c k e t s 0 0 0 0 0 0 0 x 3 1 2 C r x _ p o l i c e d 0 0 0 0 0 0 0 x 3 1 3 0 r x _ m a c s e c _ u n t a g g e d 0 0 0 0 0 0 0 x 3 1 3 2 r x _ m a c s e c ...

Page 54: ...RT2 link is up 2019 02 26 06 08 00 irbx info kernel PORT1 link is up 2019 02 26 06 08 06 irbx info lldp PORT1 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 06 08 14 irbx info kernel PORT2 link is down 2019 02 26 06 09 15 irbx info kernel PORT1 link is down 2019 02 26 06 09 30 irbx info kernel PORT2 link is up 2019 02 26 06 09 42 irbx info kernel PORT1 link is up 2019 02 26 06 09 46 irbx in...

Page 55: ...02 26 05 43 13 iRBX show syslog alarm info warn error critical filter by severity cr iRBX show syslog alarm iRBX show syslog alarm info cr iRBX show syslog alarm info iRBX show syslog alarm warn cr iRBX show syslog alarm warn show syslog alarm error cr iRBX show syslog alarm error iRBX show syslog alarm critical cr iRBX show syslog alarm critical iRBX show syslog facilities cr iRBX show syslog fac...

Page 56: ...ther alarms severity level e g debug which are not available for iRBX6GF refer to the table below Table 20 Alarms Severity Mapping Table Value Severity Keyword Description Examples Syslog Definition 0 Emergency emerg System is unusable This level should not be used by LOG_EMERG 1 Alert alert Should be corrected immediately Loss of the primary ISP connection LOG_ALERT 2 Critical crit Critical condi...

Page 57: ...p PORT2 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 05 20 51 irbx info lldp PORT2 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 06 07 50 irbx info lldp PORT2 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 06 08 06 irbx info lldp PORT1 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 06 09 46 irbx info lldp PORT1 discovered iRBX6GF HSR PRP Ethernet Switch 2019 02 26 06...

Page 58: ... 02 25 06 35 11 irbx info mstpd MSTP_OUT_set_state br0 RING0 0 entering learning state 2019 02 25 06 35 11 irbx info mstpd MSTP_OUT_set_state br0 RING0 0 entering forwarding state 2019 02 25 06 35 11 irbx info kernel PORT2 bridge state 2 2019 02 25 06 35 11 irbx info kernel PORT1 bridge state 3 2019 02 25 06 35 11 irbx info kernel PORT1 bridge state forwarding 120 2019 02 25 06 35 11 irbx info ker...

Page 59: ...slog status syslog enabled disk usage 8 remote server forwarding rules 2 alarm info 172 168 26 11 udp 514 iRBX iRBX how syslog system info warn error critical filter by severity cr iRBX show syslog system warn 2019 02 26 05 15 04 irbx err passwd unknown user c 2019 02 26 06 28 00 irbx warning kernel 0x8 0x0202 2019 02 26 06 40 41 irbx crit system starting up 4 5 114 2019 02 26 06 41 33 irbx err us...

Page 60: ...referrer http 192 168 10 13 index html iRBX iRBX show syslog info system 2019 03 01 00 01 27 10 info cdb admin cleared all syslog facilities 2019 03 01 00 31 01 10 info cdb admin changed syslog_remote_2 iRBX show syslog warn iRBX show syslog error iRBX show syslog critical iRBX iRBX show system Name iRBX Model iRBX6GF S LV LV D 2GSFP 2GSFP 2GCX Serial RBX64918 00001 HW Revision iRBX D006 PS0103 FM...

Page 61: ...ca Bujumbura Africa Cairo Africa Casablanca Africa Ceuta Africa Conakry Africa Dakar Africa Dar_es_Salaam Africa Djibouti Africa Douala Africa El_Aaiun Africa Freetown Africa Gaborone Africa Harare Africa Johannesburg Africa Juba Africa Kampala Africa Khartoum Africa Kigali Africa Kinshasa Africa Lagos Africa Libreville Africa Lome Africa Luanda Africa Lubumbashi Africa Lusaka Africa Malabo Africa...

Page 62: ...a Argentina San_Luis America Argentina Tucuman America Argentina Ushuaia America Aruba America Asuncion America Atikokan America Atka America Bahia America Bahia_Banderas America Barbados America Belem America Belize America Blanc Sablon America Boa_Vista America Bogota America Boise America Buenos_Aires America Cambridge_Bay America Campo_Grande America Cancun America Caracas America Catamarca Am...

Page 63: ... America Indiana Vevay America Indiana Vincennes America Indiana Winamac America Indianapolis America Inuvik America Iqaluit America Jamaica America Jujuy America Juneau America Kentucky Louisville America Kentucky Monticello America Knox_IN America Kralendijk America La_Paz America Lima America Los_Angeles America Louisville America Lower_Princes America Maceio America Managua America Manaus Amer...

Page 64: ...merica Rosario America Santa_Isabel America Santarem America Santiago America Santo_Domingo America Sao_Paulo America Scoresbysund America Shiprock America Sitka America St_Barthelemy America St_Johns America St_Kitts America St_Lucia America St_Thomas America St_Vincent America Swift_Current America Tegucigalpa America Thule America Thunder_Bay America Tijuana America Toronto America Tortola Amer...

Page 65: ...a Asia Chita Asia Choibalsan Asia Chongqing Asia Chungking Asia Colombo Asia Dacca Asia Damascus Asia Dhaka Asia Dili Asia Dubai Asia Dushanbe Asia Gaza Asia Harbin Asia Hebron Asia Ho_Chi_Minh Asia Hong_Kong Asia Hovd Asia Irkutsk Asia Istanbul Asia Jakarta Asia Jayapura Asia Jerusalem Asia Kabul Asia Kamchatka Asia Karachi Asia Kashgar Asia Kathmandu Asia Katmandu Asia Khandyga Asia Kolkata Asia...

Page 66: ...a Samarkand Asia Seoul Asia Shanghai Asia Singapore Asia Srednekolymsk iRBX show uptime command show version command show vlans command iRBX show uptime 5d 17 57 51 iRBX iRBX show version show version Version 4 5 114 Built 2019 02 21 iRBX iRBX show vlans Vlan Ports 1 1 2 3 4 5 6 0x7f Management VLAN 1 Port Panel PVID Egress PORT1 P1 A 1 untagged PORT2 P2 B 1 untagged PORT3 P4 A 1 untagged PORT4 P5...

Page 67: ...nd 5 ip Configure IPv4 settings ip command 6 lldp Link Layer Discovery Protocol lldp command 7 no Negate a command or set its defaults no command 8 ntp Network Time Protocol ntp command 9 password Change password password command 10 port Configure Port port command 11 ptp Precision Time Protocol ptp command 12 reboot Halt and perform a cold restart reboot command 13 redundancy Ethernet IEC 62439 3...

Page 68: ...nmp trap manager SNMP trap network manager IP address iRBX config alarm iRBX config alarm exit iRBX config iRBX config alarm monitor ports monitor ports Alarm if ports are down iRBX config alarm monitor ports 6 iRBX config alarm monitor ports 7 Syntax error Illegal parameter iRBX config alarm monitor ports 1 2 3 4 5 6 iRBX config alarm iRBX config alarm monitor power monitor power Alarm if power s...

Page 69: ...10 1 seq 3 ttl 64 time 1 000 ms 64 bytes from 192 168 10 1 seq 4 ttl 64 time 4 000 ms 192 168 10 1 ping statistics 5 packets transmitted 5 packets received 0 packet loss round trip min avg max 1 000 2 000 4 000 ms iRBX config RBX config system do show banner config date ip lldp log auth log web mac_table ntp ports ptp redundancy rstp snmp ssh stats system temperature time version vlans iRBX config...

Page 70: ...r generator 17 852000 random dd urandom read with 3 bits of entropy available done Starting lighttpd OK iRBX config ip iRBX config ip Comments address Set management IP address dns1 Set DNS server 1 dns2 Set DNS server 2 exit Exit from IPv4 settings mode gateway Set default gateway management vlan Set management VLAN iRBX config ip iRBX config ip address A B C D mask IP address iRBX config ip addr...

Page 71: ...ement vlan 4 iRBX config ip iRBX config lldp iRBX config lldp Comments disable Disable lldp enable Enable lldp exit Exit from lldp configuration mode iRBX config lldp iRBX config lldp iRBX config lldp enable 2018 04 18T21 27 24 WARN lldpctl unable to watch for neighbors End of file reached 2018 04 18T16 27 26 INFO lldpctl LLDP PortID TLV type set to new value ifname 2018 04 18T16 27 26 INFO lldpct...

Page 72: ...X config iRBX config no interlink interlink Unset port as interlink iRBX config no interlink iRBX config no vlan 1 iRBX config iRBX config ntp iRBX config ntp Comments disable Disable ntp enable Enable ntp exit Exit from ntp configuration mode server1 Add time server 1 server2 Add time server 2 sync Sync time now iRBX config ntp iRBX config ntp disable iRBX config ntp iRBX config ntp enable NTP mi...

Page 73: ... server1 Add time server 1 server2 Add time server 2 iRBX config ntp server1 1 pool ntp org iRBX config ntp server2 2 pool ntp org iRBX config ntp iRBX config ntp sync Wed Apr 18 16 40 32 UTC 2018 iRBX config ntp iRBX config password String username iRBX config password string iRBX config port 2 iRBX config port2 iRBX config port2 Comments disable Disable port enable Enable port exit Exit from por...

Page 74: ...BX config port6 exit iRBX config exit iRBX iRBX config port2 vlan number in the range 1 4095 iRBX config port2 pvid pvid Set port default vlan iRBX config port2 tapvid 10 iRBX config port1 iRBX config port2 tagged tagged Set port egress tagged mode cr iRBX config port2 tagged iRBX config port2 iRBX config port2 do show vlans Vlan Ports 1 2 3 4 5 6 0x7f Management VLAN 1 Port Panel PVID Egress PORT...

Page 75: ...ck sync to PTP time vlan VLAN ID for PTP messages iRBX config ptp iRBX config ptp iRBX config ptp disable iRBX config ptp iRBX config ptp iRBX config ptp enable iRBX config ptp iRBX config ptp exit iRBX config iRBX config ptp mode mode enable or disable tagging of PTP traffic iRBX config ptp mode tagged setting PTP VLAN 0 PCP 4 iRBX config ptp mode untagged iRBX config ptp iRBX config ptp one step...

Page 76: ... redundancy configuration mode mode Set redundancy mode netid Set PRP NetID iRBX config redundancy iRBX config redundancy iRBX config redundancy exit iRBX config iRBX config redundancy iRBX config redundancy Mode Redundancy mode HSR PRP or HSR PRP bridge modes HSR PRP A for LAN A or HSR PRP B for LAN B iRBX config redundancy mode HSR 13654 053000 0x8 0x0202 Redundancy using HSR mode with I Port on...

Page 77: ...D iRBX config redundancy netid 1 6 PRP NetID iRBX config redundancy netid 6 0x8 0x0202 Redundancy using HSR mode with I Port on PORT5 iRBX config redundancy iRBX config rstp iRBX config rstp Comments disable Disable rstp protocol domain Set bridge separate domain id enable Enable rstp protocol exit Exit from rstp configuration mode fdelay Set bridge forward delay hello Set bridge hello time maxage...

Page 78: ...rstp enable 14645 112000 PORT6 state disabled 122 2018 04 17 16 07 37 main Sanity checks succeeded 14648 140000 device RING0 entered promiscuous mode 14648 144000 device PORT1 entered promiscuous mode 14648 150000 device PORT2 entered promiscuous mode 14649 431000 device PORT3 entered promiscuous mode 14650 439000 device PORT4 entered promiscuous mode 14651 618000 device PORT5 entered promiscuous ...

Page 79: ...it iRBX config iRBX config rstp fdelay Number in range 4 30 default is 15 iRBX config rstp fdelay 5 CTL_set_cist_bridge_config Got return code 0 1 br0 Configured Bridge Times don t meet 2 Bridge Forward Delay 1 second Bridge Max Age Couldn t change bridge bridge_forward_delay iRBX config rstp maxage 6 iRBX config rstp fdelay 5 iRBX config rstp iRBX config rstp hello Number in range 1 10 default is...

Page 80: ...rstp port configuration mode member Participate in protocol p2p Identify point to point link default is auto path cost Set path cost port priority Set port priority iRBX config rstp port R 3 exit iRBX config rstp port R 7 iRBX config rstp port R 7 iRBX config rstp port R 3 admin edge Choice yes no iRBX config rstp port R 3 admin edge yes iRBX config rstp port R 3 iRBX config rstp port R 3 auto edg...

Page 81: ... 200000000 default is 0 iRBX config rstp port R 3 path cost 100 iRBX config rstp port R 3 iRBX config rstp port R 3 port priority Port priority a multiple of 16 in range 0 240 default is 128 iRBX config rstp port R 3 port priority 64 iRBX config rstp port R 3 iRBX config rstp priority Number in range 0 15 Priority is the number multiplied by 4096 default is 8 iRBX config rstp priority 9 iRBX confi...

Page 82: ...ng PORT3 down yes yes 100 64 auto yes yes disabled discarding PORT4 down yes no 0 128 auto no yes disabled discarding PORT5 down yes no 0 128 auto no yes disabled discarding PORT6 up yes yes 100 128 auto yes yes designated forwarding 3922 msec iRBX config rstp iRBX config save iRBX config iRBX config snmp iRBX config snmp Comments community Set community disable Disable snmp protocol enable Enable...

Page 83: ...p v3 user 1 maurin MD5 or SHA hash function iRBX config snmp v3 user 1 maurin SHA AES 128 or DES encryption algorithm iRBX config snmp v3 user 1 maurin SHA DES read only or read write access mode iRBX config snmp v3 user 1 maurin SHA DES read only password 6 16 characters password cr iRBX config snmp v3 user 1 maurin SHA DES read only is5communication createUser maurin SHA is5communication DES rou...

Page 84: ... in data etc ssh_host_rsa_key Your public key has been saved in data etc ssh_host_rsa_key pub The key fingerprint is ab ae 9c eb 96 d0 a8 1a 3f 6a a0 d2 02 54 3d 2d root iRBX The key s randomart image is RSA 1024 E o o S o o o o o o o Wed Apr 18 11 12 15 UTC 2018 Wed Apr 18 11 12 15 UTC 2018 Generating public private dsa key pair Your identification has been saved in data etc ssh_host_dsa_key Your...

Page 85: ...age is ECDSA 256 o E X B o o o o Wed Apr 18 11 19 29 UTC 2018 Wed Apr 18 11 19 29 UTC 2018 Generating public private ed25519 key pair Your identification has been saved in data etc ssh_host_ed25519_key Your public key has been saved in data etc ssh_host_ed25519_key pub The key fingerprint is cb ec ee 51 b4 a5 65 ec 4b 94 07 a5 9c e4 24 6d root iRBX The key s randomart image is ED25519 256 BE O S o...

Page 86: ... Configure facility remote Configure remote forwarding rule restart Restart syslog service iRBX config syslog iRBX config syslog clear clear Clear all facilities cr iRBX config syslog clear iRBX config syslog iRBX config syslog defaults defaults Reset syslog configuration to defaults iRBX config system defaults iRBX config syslog iRBX config syslog disable disable Disable syslog service cr iRBX co...

Page 87: ...r critical cr iRBX config syslog alarm severity warn iRBX config syslog alarm severity error iRBX config syslog alarm iRBX config syslog alarm enable iRBX config syslog alarm iRBX config syslog alarm do show syslog alarm lldp rstp system web 2019 02 25 06 07 24 irbx info cdb admin cleared all syslog facilities 2019 02 25 06 35 09 irbx info kernel PORT1 link is up 2019 02 25 06 35 09 irbx notice al...

Page 88: ...xit exit Exit from facility configuration mode cr iRBX config syslog alarm exit iRBX config syslog alarm iRBX config syslog remote 1 64 rule id number iRBX config syslog remote 2 1 64 rule id number iRBX config syslog remote 2 alarm lldp login rstp ssh system web iRBX config syslog remote 2 alarm info warn error critical iRBX config syslog remote 2 alarm info to iRBX config syslog remote 2 alarm i...

Page 89: ...ions Welcome to iS5 Communications iRBX config system iRBX config config system date YYYYMMDDHHMM type 12 digits of date and time iRBX config system date 201902251102 Mon Feb 25 11 02 00 UTC 2019 iRBX config system iRBX config system iRBX config system exit iRBX config iRBX config system location String system location iRBX config system location Earth iRBX config system iRBX config system name St...

Page 90: ...26 05 51 09 UTC 2019 System Uptime 1d 03 50 04 Software Version iRBX D 4 5 114 Software Date 2019 02 21 Power supply 1 2 ON OFF Firmware Bank 0 iRBX D firmware 4 5 112 20190215 backup Firmware Bank 1 iRBX D 4 5 114 20190221 active iRBX config system iRBX config system iRBX config vlan 1 iRBX config vlan1 Comments exit Exit from vlan configuration mode ports Configure port membership iRBX config vl...

Page 91: ...T6 P6 8 tagged iRBX config vlan3 iRBX config vlan3 exit iRBX config iRBX config web iRBX config web Comments acl Set access control lists disable Disable web enable Enable web exit Exit from web configuration mode session timeout Set web session auto logout duration in minutes 0 no timeout ssl Configure ssl iRBX config web iRBX config web acl iRBX config web acl Comments clear Clear all acl entrie...

Page 92: ...g web iRBX config web enable Stopping lighttpd OK Starting lighttpd OK iRBX config web iRBX config web exit iRBX config iRBX config web session timeout session timeout Set web session auto logout duration in minutes 0 no timeout iRBX config web session timeout iRBX config web session timeout 0 iRBX config web iRBX config web ssl iRBX config web ssl Comments cert delete Delete certificate cert expo...

Page 93: ...nformation that will be incorporated into your certificate request What you are about to enter is what is called a Distinguished Name or a DN There are quite a few fields but you can leave some blank For some fields there will be a default value If you enter the field will be left blank Country Name 2 letter code CA CA 720184448 error 0D07A097 asn1 encoding routines ASN1_mbstring_ncopy string too ...

Page 94: ...xplorer 5 0 or later It is based on Java Applets with an aim at reducing network bandwidth consumption and enhances access speed in a viewing screen Note By default IE 5 0 or later versions do not allow Java Applets to open sockets The browser settings need to be explicitly modified to enable Java Applets to be used on network ports The default values are as below IP Address 192 168 10 1 Subnet Ma...

Page 95: ... screen appears Click 4 The login screen appears see Figure 11 Login Screen Figure 11 Login Screen 5 Enter the username and password The default username and password are admin 6 Click OK The main interface of the Web Management appears see Figure 12 Figure 12 Main Interface or System tab ...

Page 96: ...mber Model Revision Location Change the name for the Location Chip ID It s a read only field Firmware Version iRBX D 4 5 114 2019 02 21 Firmware Mode CPU MAC Address E8 E8 75 00 03 54 MAC Address E8 E8 75 00 03 55 Time Figure 13 System tab Time The following table describes the labels for the System tab Time screen Label Description Date Enter the current date The format is yyyymmddhhii Timezone F...

Page 97: ...t is shown Gateway Set Gateway address The default is shown DNS1 Enter IP address corresponding to DNS1 Domain Name Server 1 name Format is A B C D e g 8 8 8 8 DNS2 Enter IP address corresponding to DNS2 name Format is A B C D VLAN Set management VLAN The default value is 1 Save Click to save changes Reload Click to undo any changes made locally and revert to previously saved values Maintenance Fi...

Page 98: ...Configuration Figure 17 Configuration Interface The following table describes the labels for the Configuration Interface screen Label Description Configuration Restore Import Select a configuration file and import it Configuration Backup Export Click Backup and the following screen appears Select Open with or Save file indicating also where to save the file Configuration Factory reset Select this ...

Page 99: ...box PORT3 To have an alarm warning if this port is down add a checkmark in the Monitor box PORT4 To have an alarm warning if this port is down add a checkmark in the Monitor box PORT5 To have an alarm warning if this port is down add a checkmark in the Monitor box PORT6 To have an alarm warning if this port is down add a checkmark in the Monitor box Power Supply 1 To have an alarm warning if the P...

Page 100: ...the duration of the alarm e g 2019 02 26 04 09 27 Save Click to save changes Reload Click to undo any changes made locally and revert to the saved values Alarms to generate SNMP trap Figure 20 Alarms to generate SNMP trap Interface The following table describes the labels for the Alarms to generate SNMP trap screen Label Description Manager Enter the Manager description Community Enter the Communi...

Page 101: ...ollowing table describes the labels for the Banner Interface screen Label Description Banner To change the default text in the Banner enter new text in the box Save Click to save changes Reload Click to undo any changes made locally and revert to previously saved values Syslog Figure 23 Syslog Interface ...

Page 102: ...e screen Label Description Enable To monitor disk usage add a checkmark in the box Defaults If that is successful the following message appears Success Syslog defaults set Restart Click to undo any changes made locally and revert to previously saved values Facilities Figure 25 Facilities Syslog Interface The following table describes the labels for the Facilities Syslog screen ...

Page 103: ...ty Recent Event It show the name of the most recent event Click to save changes Clear All Click to clear changes Reload Click to undo any changes made locally and revert to previously saved values Search Figure 26 Search Syslog Interface When lldp is entered in the Search box the result is as shown above Forward syslog to a remote server Figure 27 Forward syslog to a remote server Syslog Interface...

Page 104: ...le describes the labels for the Syslog Remote Rule Entry Interface screen Label Description Facility Select a facility from the drop down list The options are alarm lldp login rstp system web Severity Select a severity The options filters are info warn error and critical The default is info Server Enter server IP address Protocol Select a facility from the drop down list The options are tcp Transm...

Page 105: ...ollowing table describes the labels for the Redundancy Mode Interface screen Label Description HSR HSR is the default redundancy protocol option If you want to switch to another redundancy mode click one of the boxes below PRP To switch to PRP add a checkmark to the box adjacent to the label HSR PRP A To switch to HSR PRP A for LAN A Dual RedBox A add a checkmark to the box adjacent to the label H...

Page 106: ... saved ones Note iRBX6GF is using PRP mode with PORT5 as an I Port Interlink port as seen in dimmed field next to I PORT label Port 5 is I Port when HSR PRP A B Dual RedBox mode is in use For more details on Dual RedBox see Section 7 3 HSR PRP Dual RedBox Mode Redundancy Ring Nodes IreNodes Table Figure 31 Redundancy Ring Modes IreNodes Table Interface IreNodes Table shows all dynamic entries avai...

Page 107: ... Tagged To set a port as Tagged check the box adjacent to the ports label Tagged packets contain an 802 1Q dot1q VLAN tag with a PVID for more details refer to IEEE 802 1Q 1 The default value is untagged not checked PVID To assign PVID port VLAN ID enter a number in the appropriate box The default value is 1 A Port VLAN ID pvid is a default VLAN ID that is assigned to an access port to designate t...

Page 108: ...ure 34 Ports Status Interface This table shows read only information about all ports Same information can be accessed when the show ports command is used Ports Statistics Figure 35 Ports Statistics Interface This table shows read only information about ports statistics Ports statistics can be accessed by using the show stats command 10 4 Protocols This web page shows all protocols available for iR...

Page 109: ...ee Protocol PTP Precision Time Protocol LLDP Link Layer Discovery Protocol NTP Network Time Protocol SNMP Simple Network Management Protocol Figure 36 Protocols Interface RSTP RSTP Bridge Figure 37 RSTP Bridge Interface The following table describes the labels for the RSTP Bridge screen ...

Page 110: ...ge transmits configuration BPDUs 5 RSTP is typically able to respond to changes within 3 Hello Time default 3 times 2 seconds or within a few milliseconds of a physical link failure Max Age Enter a value Max Age is in range of 6 to 40 default is 20 The maximum age timer specifies the maximum expected arrival time of hello BPDUs If the maximum age timer expires the bridge detects that the link to t...

Page 111: ...the port s Priority The port priority is in range of 0 to 240 in increments of 16 default is 128 P2P Identify the P2P point to point link default is auto P2P connection is a permanent direct communication link between two parties Other values are no yes Admin Edge Edge ports transition directly to the forwarding state and so the protocol does not need to wait for BPDUs to be received on edge ports...

Page 112: ...for which the value is forwarding Discarding means that no user data is sent to a port and forwarding state of a port a fully operational port Note these values are assigned during Configuration Factory Reset Save Click Save to save the changes Defaults Click Defaults to go back to all default values Reload Click to undo any changes made locally and revert to the saved ones ...

Page 113: ...nd control system to a high degree of accuracy and precision PTP achieves accuracy when hardware timestamping is used IEEE 1588 2008 standard has defined two types of switches or routers which specifically deal with their own queues One device is called a transparent clock This type performs hardware timestamps when a sync message arrives or departs the transparent clock Figure 39 PTP Interface Co...

Page 114: ... enabled sync of the host clock to PTP time Tagged To configure the sending of tagged PTP packets add a checkmark in the box next to label Tagged The packet format for PTP messages can be 802 1q tagged or untagged When PTP packets are sent on the native VLAN in E2E Transparent Clock Mode they are sent as untagged packets This is the default option VLAN ID Enter a value for VLAN ID for PTP messages...

Page 115: ...nd Time to Live TLV The mandatory TLVs are followed by any number of optional TLVs The frame ends with a special TLV named end of LLDPDU in which both the type and length fields are 0 To see the LLDP configuration Global statistics and LLDP mandatory TLVs use do show lldp command On the status report TTL is the length of time in seconds for which an LLDP neighbor retains the advertised data before...

Page 116: ...ncoming LLDP advertisements LLDP Neighbor Table Local Port This is a read only value of PORT5 This is the LLDP interface Local means assigned locally by LLDP Remote Chassis Name This is a read only field e g it shows iES22GF Remote Chassis Desc This is a read only field as shown above Remote MAC This is a read only value of e8 e8 75 00 08 5a This is an ChassisID where the chassis ID subtype is the...

Page 117: ...ter the correct time zone in the timezone UTC field Figure 43 NTP Interface The following table describes the labels for the NTP Interface screen Label Description Enable Add a checkmark to enable NTP Time This is a read only field showing system time Timezone UTC Universal Coordinated Time Timezone The current for Toronto is 4 Server 1 Add a time Server 1 The default is 1 pool ntp org The pool nt...

Page 118: ...servers printers hubs switches and routers on an Internet Protocol IP network Figure 44 SNMP Interface The administrative framework for SNMPv2 associates each message with a community So SNMP Ver 2 is commonly known as Community based SNMPv2 SNMPv2C 2 A security shortcoming of SNMP v2c is that the community strings used for authentication are communicated in cleartext over the network and can pote...

Page 119: ...ield e g read write as shown in Figure 45 There are 2 options read only or read write To create a new community on the row of the dialog box click The Edit Community Entry appears Community enter a name e g private Privilege select one of the 2 options read only or read write After selection click OK to save your choices or Cancel to discard them For community string to be deleted click The follow...

Page 120: ...s should not contain or be based upon corporate culture or name Public and private community strings should not match Hash Select a Hash function from the drop down menu MD5 Message Digest algorithm has a hash value of 128 bits and as of 2010 the CMU Software Engineering Institute considers MD5 cryptographically broken and unsuitable for further use Encryption The encryption options are DES Data E...

Page 121: ...new row to the table see Figure 47 Repeat adding numbers as needed The first row shows the default VLAN 1 with all ports members Port Membership Enter port numbers in this field Save Click Save to save new VLAN and its ports membership Note it may take up to 30 seconds to save the date At the end the following message will appear For VLAN to be deleted click It will be deleted without any extra no...

Page 122: ... labels for the Services Web tab Interface screen Label Description Control Session Timeout Enter Session duration Apply Click Apply to save the changes Reload Click to undo any changes made locally and revert to the saved ones Web Service Stop Click to stop web service Restart Access Control Rules Configure IP networks which are allowed to access SNMP ...

Page 123: ...lowing Edit ACL Entry dialog box will appear Access control entry ACE is an entry in an access control list ACL that will grant or deny a user or group access to a resource Choose Access Select Access The options are allow and deny The default is allow Enter Pattern In Edit ACL Entry box enter a pattern e g 192 168 1 1 24 Click OK to confirm To delete a record in the Access Control Rules table cli...

Page 124: ...SH tab Interface screen Label Description SSH Enable To enable SSH add a checkmark in its adjacent box Keygen status Regen Keys Click Regen Keys to re generate keys Reload Click to undo any changes made locally and revert to the saved ones When you click Regen Keys the following message appears Success Regeneration is in process it may take up to 20 minutes for the process to complete Next to the ...

Page 125: ...Parallel Redundancy Protocol NTP Time Synchronization Multi User support Admin Guest SNMP support SSH Support Login Banner for CLI and WebUI Inband and dedicated Management interface LLDP support WebUI Management Power Input Power Redundant Power Supplies Dual DC Inputs 9 36VDC Dual DC Inputs 36 75VDC or Dual Input 110 370VDC or 90 264VAC Power Consumption Typ Up to 20 W Overload Current Protectio...

Page 126: ...613 IEC 62439 3 EMI FCC Part 15 Class A CISPR Class A EN55022 EMS IEC 61000 4 2 ESD IEC 61000 4 3 Radiated RFI IEC 61000 4 4 Burst IEC 61000 4 5 Surge IEC 61000 4 6 Induced Conducted RFI IEC 61000 4 8 IEC 61000 4 11 Warranty 5 years For dimensions refer to the latest revision of the products datasheet http is5com com products irbx6gf ...

Reviews: