iES24G Series User’s Manual
iS5 Communications Inc.
11
2.4
Front Panel LEDs
the
LED
Color
Status
Description
PW1
Green
On
When power supply 1 is on,
the LED will be green.
PW2
Green
On
When power supply 2 is on,
the LED will be green.
STA
Green
On
When the power module is
in PWR UP state, the green
LED lights on.
DEF
Green
On
System resets to default
configuration.
RUN
Green
Slowly blinking
System is operating
continuously.
PWR
Green
On
DC power module activated.
Ping
Green
Blinking
When the LED is on, the
iRing is activated.
RMT
Green
Blinking
System is accessed remotely.
iRing
Green
On
Ring enabled.
Slowly blinking
Ring has only One link. (lacks
one link to build the ring)
Fast blinking
Ring work normally.
R.M
Green
On
Ring Master.
Fault
Amber
On
Indicates unexpected
event occurred.
10/100/1000Base-T(X) Giga Ethernet ports
10/100
LINK
Amber
On
Port speed 10/100 link up.
1000 LINK
Green
On
Port speed 1000 link up
ACT
Amber
Blinking
Data transmitted.
SFP
LNK
Green
On
Port link up.
ACT
Green
Blinking
Data transmitted
2.5
Power Connections
The Phillips Screw Terminal Block, located on the back of the unit, has Phillips screws with compression
plates, allowing either bare wire connections or crimped terminal lugs. The use of #6 size ring lugs is
recommended to ensure secure and reliable connections under severe shock or vibration. The terminal
block comes with a safety cover which must be removed before connecting any wires. This cover must be
re-attached after wiring to ensure personnel safety
.
The iES24G series supports dual redundant power supplies (PWR1 and PWR2). There are 3 options:
1.
LV: Single or Dual Input 12-36VDC
2.
MV: Single or Dual Input 36-72VDC
3.
HV: Single or Dual Input 88-300VDC or 85-264VAC.