16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
NOTES:
• It is not recommended to terminate
exhaust vent on the prevailing wind
side of the house.
Wall
Maintain minimum clearances specified by
vent manufacturer between wall and pipe.
If you vent to the furthest wall, the vent pipe
must maintain the specified clearance parallel
to the other wall.
Top View Illustration
Wall
1" Min.
1" Min.
6” (152 mm)
Minimum
Hearth Pad / Floor Protection
45 Degree
Elbow
2” (51 mm)
Minimum
Figure 17 - Montage 32FS, Parallel Through the Wall
Wall
Outdoors
Standard Horizontal Installation Configurations
Montage™ 32FS
NOTE:
Horizontal run of pipe
requires 1/4” (7 mm) rise per foot.
Figure 16 - Montage 32FS, Corner Through the Wall
u
Refer to vent manufacturer's
installation instructions for minimum
vent clearance.
Ne pas installer de coudes
successifs immédiatement à
l’arrière du poêle, quelque
soit l’installation.
u
u
u
u
Refer to vent manufacturer's
installation instructions for minimum
vent clearance