Wall Straps 

Required Every

4 Feet Minimum

Standard Vertical Installation Configurations
Model: Montage™ 32FS

This free-standing model may be connected to an existing flue or by 

installing listed type “PL” vent pipe. If a liner is run all the way to the 

top of the existing chimney, the existing flue should be sealed with a 

steel plate.  Start a vertical run with a Tee at the back of the stove.  Other 

options are illustrated below. 

Preferred Installation – Vertical Vent Through the Roof

This venting configuration allows for the best stove performance. The 

vertical pipe promotes natural draft and with the chimney inside the 

dwelling, the flue gases stay warm, thus rising at a consistent rate.

 

NOTE

: See 

Pages 11 and 12

 for Vent Termination Requirements

Clean-Out

Tee

Flashing

Listed Rain Cap

Extend Pipe to the Top 

if Existing Chimney is 

Corroded or Damaged

Pipe Increaser

Existing 

Chimney Pipe

Optional 

Clean-Out 

Access Door

Optional Complete 

Liner and Listed 

Termination Cap

Figure 18 - Exterior Vertical Vent

Figure 19 - Vertical Vent Into a Masonry Flue 

Figure 20 - 

Vertical Vent Through the Roof

Figure 21 - 

Interior Vertical Vent into an Existing Class A Chimney

Listed Rain Cap

Listed Rain Cap

Listed Rain Cap

Maintain clearances 

specified by vent

manufacturer

Maintain clearances 

specified by vent

manufacturer

Maintain clearances 

specified by vent

manufacturer

Summary of Contents for 32FS

Page 1: ...for continuous use as a primary heat source A French manual is available upon request Order P N 900117 00 Ce manuel d installation est disponible en francais simplement en faire la demande Numéro de la pièce 900117 00 This appliance must be properly installed and operated in order to prevent the possibil ity of a house fire Please read this entire manual before installation and use of this pellet ...

Page 2: ...HP dealer for more information on approved pellet fuels 12 CONTINUOUS OPERATION When operated correctly this appliance cannot be overfired Continuous operation at a maximum burn can however shorten the life of the electri cal components blowers motors and electronic controls and is not recommended Typical approved operation would includerunningatthelowtomidrangesettingwithoccasional running on the...

Page 3: ... room heater The safety listing label is located on an inside hopper surface of the pelletstove Pleasereadthissafetylabelcarefully Itcontainsimportant information about installation and operation of this appliance This appliance is tested and listed for residential and commercial installation according to current national and local building codes as A Free Standing Room Heater A Manufactured Home ...

Page 4: ... any home we recommend installing smoke detectors If possible install the smoke detector in a hallway adjacent to the room to reduce the possibility of occasional false activation from the heat produced by these appliances If your local code requires a smoke detector be installed within the same room you must follow the requirements of your local code Check with your local building department for ...

Page 5: ... this appliance must be met within the space where it will be installed Ventilation is essential when using a solid fuel burning heater In well insulated and weather tight homes it may inhibit the rate the exhaust flows through the venting system caused by a shortage of air in the home The lack of air is caused by many common household appliances which exhaust air from the home such as a furnace h...

Page 6: ...t 4 102 mm B Back wall to unit 2 51 mm C Side wall to unit Corner 1 25 mm D Max Depth of Alcove u 24 610 mm E Flue to Wall v 3 76mm u Minimum Alcove Measurements Height 48 1220 mm x Width 31 788 mm x Maximum Depth 24 610 mm v See vent manufacturer to verify clearances Table 1 Combustible Rear Wall or Alcove Clearance to Combustibles Figure 3 Corner Clearance to Combustibles B A E D A E C C Combust...

Page 7: ...PIPE With listed termination kit If installation requires in excess of 11 of pipe it is recommended a 4 diameter pipe be used MANUFACTURED HOME Requires outside air for com bustion Use a galvanized or stainless steel pipe for duct Minimum duct size 1 5 8 dia CLEARANCES TO COMBUSTIBLES Ensure all clearances are main tained in accordance to instruc tions contained on product safety label and in comp...

Page 8: ...n standards CSA C22 1 latest edition in Canada as well as any local codes SeePages11through17foradditionalinformationonventingrequire ments WARNING DO NOT INSTALL THIS STOVE IN A SLEEPING ROOM IN A MANUFACTURED HOME CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR WALLS CEILING ROOF MUST BE MAINTAINED Figure 4A Manufactured Home Installation Manufactured Home Exhaust Vent Pipe Insta...

Page 9: ...DETAIL B DETAIL B SEE DETAIL C DETAIL C Rear Pallet Bracket Rear Lag Screw Front Lag Screw Figure 5A Front Lag Screw Figure 5B Rear Lag Screw and Pallet Bracket Installation Check List It is strongly recommended that you have an IHP dealer install your stove If you install your stove yourself you should review your installation plan with an IHP dealer Check list Check off each item as you proceed ...

Page 10: ...ector locations After you have begun operation of your appliance q Review the routine cleaning maintenance information q Enjoy the warmth from your new IHP pellet stove Damper Location and Adjustment Damper Air Control Located behind the right side panel on model Montage 32FS Adjustment Procedure Using a 1 4 nut driver or socket loosen the damper setscrew see Figure 6 Adjust in 1 4 increments unti...

Page 11: ...tside of pipe unlessotherwisespecifiedbyventmanufacturer alldiameters 3 75 mm and 4 100 mm A support bracket must be installed every 4 feet 1 2 m of pellet vent pipe on the exterior wall of the house unless otherwise specified by vent manufacturer It is not recommended to terminate exhaust vent on the prevailing wind side of the house In Canada where the venting may pass through a wall or partitio...

Page 12: ...rmitted From Eave Vertical Terminal Vertical Terminal Fixed Closed Able To Open A A B B B B C D E F G H J K L M N 24 610mm B Air Supply Inlet 24 610mm Figure 9 D The distance from the bottom of termination to grade is 12 305 mm minimum unless otherwise specified by the vent manufacturer This is conditional upon plants and nature of grade surface Be careful to choose alocationfortheventterminationw...

Page 13: ...als for additional requirements for your area To pass inspection in nearly any jurisdiction the chimney must meet both safety and exhaust flow requirements The 3 by 2 by 10 rule applies to both masonry and factory built chimneys Ref USA National Standard NFPA 211 latest edition and Canada National Standard CSA B365 01 latest edition Vents installed with a listed cap shall terminate in accordance w...

Page 14: ...Degree Elbow B 1 Horizontal Pipe C 45 Degree Elbow D Standoff Braces E 8 Vertical Pipe F 2 Horizontal Pipe G 90 Degree Tee H Wall Thimble NOTE All equivalent pipe styles shown for model Montage 32FS Type of Pipe of Elbows or Feet of pipe Equivalent Feet Total Equivalent Feet 90 Elbows Tee A G x 5 Feet 1 5 m 45 Elbows C x 3 Feet 1 m Horizontal B F x 1 Feet 3 m Vertical E x 5 Feet 15 m Table 3 Sampl...

Page 15: ...ble Do not position the back of the stove closer than 2 51 mm from the wall see Clearances Page 6 4 Install listed type PL 45 degree elbow with rodent screen or cap on outside end of pipe The Inlet shall remain free of obstruction while unit is in operation and constructed in a manner so as to prevent material from dropping into the inlet or into the area beneath the dwelling The inlet shall also ...

Page 16: ... Minimum Hearth Pad Floor Protection 45 Degree Elbow 2 51 mm Minimum Figure 17 Montage 32FS Parallel Through the Wall Wall Outdoors Standard Horizontal Installation Configurations Montage 32FS NOTE Horizontal run of pipe requires 1 4 7 mm rise per foot Figure 16 Montage 32FS Corner Through the Wall u Refer to vent manufacturer s installation instructions for minimum vent clearance Ne pas installer...

Page 17: ...ical pipe promotes natural draft and with the chimney inside the dwelling the flue gases stay warm thus rising at a consistent rate NOTE See Pages 11 and 12 for Vent Termination Requirements Clean Out Tee Flashing Listed Rain Cap Extend Pipe to the Top if Existing Chimney is Corroded or Damaged Pipe Increaser Existing Chimney Pipe Optional Clean Out Access Door Optional Complete Liner and Listed T...

Page 18: ...e fuel will pile up in the UltraGrate see Page 10 If the damper is too far outward the flame might be extinguished because of too much combustion air See Page 20 for further instructions on adjusting damper using thermostat vs manual modes No 7a Followthetroubleshooting section in this manual Contact your IHP dealer for further assistance 10 Thank you for purchasing an IHP Pellet Stove END Does th...

Page 19: ...wer IMPORTANT NOTE If the fuel feed trim or combustion air trim needs to be adjusted contact your dealer or qualified technician to calibrate internal software The trim controls should only be adjusted for the proper flame if all other options did not achieve proper adjustment It is recommended that the damper be used to fine tune your stove to your particular fuel and installation configuration s...

Page 20: ...ur flame should be bright yellow under normal operations If your flame becomes reddish orange your stove probablyneedsroutinemaintenance Excessiveamountsoffly ashbuild up in the UltraGrate clinkers in the UltraGrate or leakage of air if the UltraGrate is not properly seated will starve the fire for air See Routine Maintenance for information on cleaning the stove If the problem per sists review th...

Page 21: ...smoky or red orange flame excessive ash or soot excessive buildup on glass fuel may pile up Contributing factors High Altitude Lack of oxygen Restrictive Venting elbows horizontal runs cold external chimneys etc Dirty Poor Quality Fuel Lack of Maintenance NOTE Excessiveamountsoffly ashbuilt upintheUltraGrate clinkers in the UltraGrate or leakage of air if the grate is not properly seated will star...

Page 22: ...wood pellets in a dry place to prevent them from absorb ing excess moisture Do Not store your wood pellets within the clearance zone of the stove Do Not store your wood pellets in a place that would block removal of the ash pan or block access to refueling the hopper FUEL CAUTION The use of unapproved dirty wet and or high salt content fuel will void the warranty ROUTINE MAINTENANCE Wood pellets m...

Page 23: ...le plate to the left until the screw heads clear the open end of the key hole slots Remove the baffle plate diagonally through door opening The tube scraper rod can now be pulled in a more horizontal manner which allows the scraper to move more freely NOTE The baffle plate should be removed at least once a year to allow for a thorough cleaning Figure 24B Removing Baffle Plate Figure 25 Clean Behin...

Page 24: ...mplete combustion such as occurs during startup shutdown or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaustventingsystem Theexhaustventingsystemshouldbeinspected at least once every year to determine if cleaning is necessary Burningfuelwithahighashcontentoranimproperlyadjusteddamper may require more frequent cleaning and stove maintenance F...

Page 25: ... expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining Whenignitedthiscreosotemakesanextremelyhotfire Thechimneycon nector and chimney should be inspected at least once every two months duringtheheatingseasontodetermineifacreosotebuilduphasoccurred If creosote has accumu...

Page 26: ...LACED BEFORE HEATER CAN BE SAFELY OPERATED USE ONLY COMPONENTS PROVIDEDBYTHEMANUFACTURERASREPLACEMENTPARTS Small Area Paint Touch up The stove body is painted with a quality high temperature stove paint Use only model TSPK B Stove Paint Catalog H8159 Do not touch up your stove with any other paint Using one small piece of 320 grit sand paper and lightly sand the blem ish so that the edges are feat...

Page 27: ...imations only 25 1 4 Approved for Manufactured Home Installations Optional Kits Available Decorative trim kits log set window screen and 3 and 4 Quick Discon nect kits The burn grate is designed with advanced UltraGrate technology uIn Canada floor protection is required directly underneath and 2 from the sides of the flue or chimneyadaptor ThisisrecommendedintheUS vBurn times hopper capacity and B...

Page 28: ...at in the ashpan area This switch is located on the firebox base behind the convection jacket directly above the ashpan This switch is most easily accessed by removing the ashpan ThermalSwitch LowLimit Ceramic F140 20F N O G This proof of fire switch will close at 140 F and will not open until it reaches a temperature of 120 F This switch is located on the combustion blower behind the right side p...

Page 29: ...ER DIRECTLY ABOVE ASHPAN 2 BLK IGN 08 2302 MATERIAL SPECIFICATIONS MATERIAL WHITE POLYESTER 740 2 MIL PRINT TREATED ADHESIVE PERMANENT ACRYLIC ADHESIVE MATERIAL SIZE 4 X 10 TEXT BLACK DIELINE WILL NOT PRINT SUPPLIER INTERNATIONAL GRAPHICS NAMEPLATE INC 14413 NE 10TH AVE SU C VANCOUVER WA 98685 800 458 3355 REV DATE ALTERATIONS PREPARED BY CHKR NC 06 04 2008 T 3654 New Release MSJ JB JSH CRZ TOLERA...

Page 30: ...f fuel E The proof of fire switch is opening disconnecting power to the auger motor A Refill hopper B See Pelletswill not feed thisPage C Allowthe appliance to cool for 1 hour then re light Ifthestove hasbeen operating at a medium to high burn rate withtheroomair blower adjusted to low there maynot be enough air flowtodissipate the heat On higher feed rates adjust the blower speedtoahigher setting...

Page 31: ... leak the fine particles of ash into the home Clean the stove with an approved ash vacuum ONLY 6 Stovewillnotlight A The igniter element may have failed B There is not enough pellets in the UltraGrate A Check igniter element fuse in rear stove compartment Call your IHP dealer See Lighting Procedure Without Igniter Page 20 B Prime the feed system see Pre lighting Instruc tions Page 20 7 Fault A The...

Page 32: ...ket 1 per pkg 36 H7063 Hopper Lid Switch 1 per pkg 26 H7065 High Limit Auto Reset Reverse Flow Snap Switch Assembly L250 30F N C 1 per pkg on firebox base behind convection jacket above the ash pan 28 12147705 High Limit Auto Snap Switch L250 30F N C 3 per pkg on convection jacket 37 H5887 Low Limit Auto Proof of Fire Snap Switch Assembly F140 30F N O 1 per pkg 57601 Item Cat No Description 27 121...

Page 33: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 REPLACEMENT PARTS Montage 32FS 13 46 19 14 33 47 12 49 5 11 15 17 50 9 21 16 18 20 4 10 52 34 38 Includes 20 feet of thermostat wire 8 6 1 7 3 2 51 ...

Page 34: ...34 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26 27 28 31 32 33 31 57 REPLACEMENT PARTS Montage 32FS 24 28 28 37 27 40 56 44 36 30 29 34 41 23 26 45 25 22 43 54 35 55 53 42 32 ...

Page 35: ...Log Set 775077M 6 H8159 TSPK B Touch up Paint Black 7 12050093 QDPC 3 Quick Disconnect Pipe Connector 3 ref Form 506033 02 7 14M81 QDPC 4 Quick Disconnect Pipe Connector 4 ref Form 506033 02 8 H8974 RC S STAT AC Remote T Stat Alternating Current RCVR 9 H8865 RC S TOUCH Remote Touch Screen Thermostat On Off 10 H8861 RC S STAT Remote LCD Stat Thermostat On Off 11 H8860 RC S 1 Remote Two Button Timer...

Page 36: ...36 NOTES ...

Page 37: ...roduct IHP will not be responsible for a damages caused by normal wear and tear accident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The use of fuels other than those outlined in the operation manual provided with the Product will voi...

Page 38: ...al File it with your other documents for future refer ence Product reference information We recommend that you record the following important information about your fireplace Please contact your IHP dealer for any questions or concerns Replacement parts See Page 32 through 34 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered th...

Reviews: