63
Appendix G: Roomba Built-in-Test Limits
The following are the limits used to PASS or FAIL a Built-in-Test.
Tested in
BiT #
Description MIN
MAX
6
Battery Voltage
12V
18V
6
Battery Temperature (C)
5
°
C
60
°
C
7,8,11,13,14 Baseline Current
-202 mA
-13 mA
7
Left Drive Current
-326 mA
-117 mA
7
Left Drive Stall Current
-749 mA
-397 mA
8
Right Drive Current
-326 mA
-117 mA
8
Right Drive Stall Current
-749 mA
-397 mA
11
Brush Current
-566 mA
-208 mA
11
Brush Stall Current
-1901 mA
-1302 mA
13
Side Brush Current
-247 mA
-52 mA
13
Side Brush Stall Current
-423 mA
-98 mA
14
Vacuum Current
-352 mA
-176 mA
14
Vacuum Stall Current
-423 mA
-299 mA
15
Internal Charging Prep Current 32
mA
71 mA
15
Internal Charging Recovery Current
241 mA
358 mA
16
Internal Charging Current
397 mA
1602 mA
17
Internal Charging Trickle Current
33 mA
72 mA
18
External Charging Prep Current 32
mA
71 mA
18
External Charging Recovery Current
241 mA
358 mA
19
External Charging Current
397 mA
1602 mA
20
External Charging Trickle Current
33 mA
72 mA
Summary of Contents for Roomba Discovery
Page 32: ...32 Charging Accessories Battery Power Supply Home Base Rapid Charger...
Page 41: ...41 Roomba Accessories Virtual Wall Remote Filters Bristle Brush Flexible Brush Side Brush...
Page 47: ...47 Appendices...
Page 82: ...82 Appendix N User Interface User Interface POWER Light...
Page 83: ...83 User Interface STATUS Light User Interface DIRT Detect...