41
XD X3 Plus
Ref. no. 40-8939-2001-04/1712
No
Possible causes
Remedies
See page
1.
Incorrect S/Z switch position
Set the S/Z switch in appropriate position
22
2.
Incorrect spoolbody position
Ensure the sensor unit is positioned upwards
26
3.
Winding disc jammed
Free and clean the winding disc
39
4.
Contaminated sensor or mirror
Clean the sensor and mirror using a mild cleaning agent
26
6.
Faulty cable connections
Check and rectify
6, 10-13
7.
Fuses blown
Replace the relevant fuse
10-13
8.
Mains supply / primary voltage fault
Check the mains supply and connections
6, 10-13
11.
Insufficient balloon control
Increase the balloon control
28
12.
Excessive output tension
Reduce the output tension
28
13.
Excessive yarn separation
Reduce the yarn separation
22
19.
Insufficient yarn store
See “low or empty yarn store” under “fault”
-
20.
Damaged balloon control
Repair/replace all defective parts
3
21.
Stop signal fault between control box and
weaving M/C
Check all connections/cable
10-13
22.
Misalignment between the bobbin and
the feeder
Realign the bobbin/feeder
-
23.
Misalignment between the feeder and
the machine
Realign the feeder/machine
-
24.
Defect yarn store sensor unit
Replace the relevant sensor unit
20
25.
Defective motor circuit board
Replace the relevant circuit board
10
26.
Defective fuse panel
Replace the relevant fuse panel
10-13
27.
Defective control box interface
Replace the relevant interface
10-13
28.
Defective feeder connection cable
Replace the relevant connection cable
-
29.
Yarn break
Re-thread the feeder
24
Fault
Check in the following order
Feeder will not start
1 - 2 - 3 - 4 - 6 - 7 - 8 - 24 - 25 - 26
Feeder will not stop
2 - 4 - 24 - 25
Low or empty yarn store
4 - 3 - 13 - 8 - 21 - 24 - 25 - 27 - 26
Input yarn breaks frequently
22 - 13
Output yarn breaks frequently
11 - 20 - 12 - 19 - 23
Fuses blow repeatedly
25 - 28
Feeder warning light flashes slowly
4
Feeder warning light flashes rapidly
3 - 8 - 27
Feeder warning light continously on
29
Fault finding