22
0
Ref. no. 40-8939-2001-04/1712
Switch off the feeder.
On feeders with S-flex, the S-flex must be detached for
making the S/Z adjustment.
See page 31-32 (Flex-brake mounting).
Grip the winding disc and, whilst pressing the orange
button on the front of the spool body, rotate the disc
until the button is felt to locate. Aligning the mark on the
winding disc with the line on the motor house gives the
zero separation position.
To adjust, press in the button and revolve the winding disc
in the appropriate direction. The separation increases from
0 to 4 mm the more the disc is rotated.
The separation must be distinct, but not excessive.
Set the direction of rotation with the switch. (The feeder is
deactivated in the standby position (0))
NOTE
On feeders with brush, choose the correct type of
brush (S, Z or Straight) depending on the direction
of the rotation. See page: 32
S/Z Adjustment
NOTE
Before starting the automatic sensors calibration,
check the following: