19
Multi yarn break sensor system
Multi yarn break sensor system
1. Power supply cable
4. Signal cable to
feeder
3. Concentrator box
6. Interface box
5. Yarn break sensor
5. Yarn break sensor
2. Extension cable
2. Extension cable
7. Feeder
Ref. no. 31-8939-0201-05/1805
1131 X2
Accessories - Multi yarn break sensor system
E. Connect the signal cable (4) between the feeder (7)
and the concentrator box. It is important that the
signal cable is connected to the correct connector in
the concentrator box.
F. Connect the power supply cable (1) between the
feeder interface box (6) and the concentrator box.
Use the connector on the upper side of the feeder
interface (see picture below).
Use the power supply connector in the concentrator
box as illustrated on page 22.
G. Turn on loom main power.
H. Choose external yarn break sensor on the feeder
setting page on the weaving machine control panel.
Dissasemble the circuit board housing from the feeder.
Plug in the cable on the circuit board (red arrow marks the
connector).
Position the cable as shown then re-assemble
the circuit board housing onto the feeder.