Reverse Logic
The default condition for the
Eyz-On
is to detect a contact closure on the alarm
inputs, but the
Eyz-On
can be configured to detect an alarm input open
condition. In this case the normal (not alarmed) state would be to use a N.C.
(normally closed) switch or relay. When the
Eyz-On
detects that the alarm
inputs are NOT closed for a minimum of 1 second an alarm input event will
occur.
This reverse logic option is not configurable through the Web Interface, but
requires a modification to the
Eyz-On
configuration file.
Trigger Events