![Irenis IRD-6000 User Manual Download Page 17](http://html1.mh-extra.com/html/irenis/ird-6000/ird-6000_user-manual_2090191017.webp)
QPSK/IP DEMODULATOR
x-Multicast Port:
Enter the UDP port number of the TS over IP stream output.
x-Switch:
each channel could be switched On/Off independently. The default value is
‘off’. To activate
the channel, you should turn on.
x-Program:
it shows all programs carried by the transport stream from the source selected. Press
<ENTER>-key and use <> <>-keys to roll up and down between the program names, where a number
in front of the program name indicates the input source:
0-xxxxx
displays the program name, which signal source is ASI.
1-xxxxx
displays the program name, which signal source is TUNER.
3-xxxxx
displays the program name which comes from the internal CI functional block.
4-xxxxx
displays the program name which comes from the internal Mux / Filter functional block.
All encrypted programs are labeled with a
‘$’
sign on the first row. Press
<ENTER>-key
to the program
just be selected to be delivered to the specified IPTV channel or to scrap by pressing
<EXIT>-key
.
System
The system menu provides information about the general functions, the surroundings equipment and
the hardware used.
System
Local
Setup
Trap IP
Addr
Unit
Name
Properties
Factory
Settings
Optional
Function
Machine
Type
Figure 7.4 System Menu
7.4.1 Local Setup
Each This equipment-x has an IP address, a network sub mask and a gateway. These must be set to
an appropriate value for the network over which the unit can be accessed by the remote control system
such as the HDMS.
IP Address:
The IP address for the unit.
Network Mask:
The network mask for the subnet to which the unit is connected.
Gateway:
The gateway for the network to which this unit is connected.
7.4.2 Trap IP Addr
The This equipment-x provides a Monitor Center IP address. You can set this to be the same IP
address of the Monitor Center, which is typically a PC in order to allow the device to send messages
to the monitor center. If the This equipment-x is connected with the HDMS remote management
system, the Trap IP address is typically set to be the IP address of the PC on which the HDMS has
been installed.
7.4.3 Unit Name
The This equipment-x allows you to edit the unit name which is displayed on the front panel LCD.
Default name is
‘Digital TV Processor”. The unit
n
ame should not be longer than 20 characters in ASCII
format.
7.4.4 Properties
You are allowed to check the properties information of the device.
MAC address:
Factory-set MAC address which is guaranteed to be unique. You cannot configure this
address.
17