QPSK/IP   DEMODULATOR 

 

 

x-Multicast Port: 

Enter the UDP port number of the TS over IP stream output.

 

x-Switch: 

each channel could be switched On/Off independently. The default value is 

‘off’. To activate 

the channel, you should turn on.

 

x-Program: 

it shows all programs carried by the transport stream from the source selected. Press

 

<ENTER>-key and use <> <>-keys to roll up and down between the program names, where a number 
in front of the program name indicates the input source:

 

0-xxxxx 

displays the program name, which signal source is ASI.

 

1-xxxxx 

displays the program name, which signal source is TUNER.

 

3-xxxxx 

displays the program name which comes from the internal CI functional block.

 

4-xxxxx 

displays the program name which comes from the internal Mux / Filter functional block.

 

All encrypted programs are labeled with a 

‘$’ 

sign on the first row. Press 

<ENTER>-key 

to the program 

just be selected to be delivered to the specified IPTV channel or to scrap by pressing 

<EXIT>-key

.

 

System

 

The system menu provides information about the general functions, the surroundings equipment and 
the hardware used.

 

 

 

System

 

 

 

 

 

 

 

 

 

 

 

 

Local 

Setup

 

 

Trap IP 

Addr

 

 

Unit 

Name

 

 

 

Properties

 

 

Factory 

Settings

 

 

Optional 

Function

 

 

Machine 

Type

 

 

Figure 7.4 System Menu

 

 

7.4.1  Local Setup

 

Each This  equipment-x has an IP address, a network sub mask and a gateway. These must be set to 
an appropriate value for the network over which the unit can be accessed by the remote control system 
such as the HDMS.

 

IP Address: 

The IP address for the unit.

 

Network Mask: 

The network mask for the subnet to which the unit is connected.

 

Gateway: 

The gateway for the network to which this unit is connected.

 

7.4.2  Trap IP Addr

 

The This  equipment-x provides a Monitor Center IP address. You  can set this to be the same IP 
address of the Monitor Center, which is typically a PC  in  order to allow the device to  send messages 
to the monitor center. If the This  equipment-x is connected with the HDMS remote management 
system, the Trap IP address is typically set to be the IP address of the PC on which the HDMS has 
been installed.

 

7.4.3  Unit Name

 

The This  equipment-x allows you to edit the unit name which is displayed on the front panel LCD. 
Default name is 

‘Digital TV Processor”. The unit 

n

ame should not be longer than 20 characters in ASCII 

format.

 

7.4.4  Properties

 

You  are allowed to check the properties information of the device.

 

MAC address: 

Factory-set MAC address which is guaranteed to be unique. You cannot configure this 

address.

 

 
 

17

 

Summary of Contents for IRD-6000

Page 1: ...QPSK IP DEMODULATOR QPSK IP Demodulator User Manual IRD 6000 QPSK IP Demodulator QPSK IP Demodulator User Manual V1 0 Version 1 0...

Page 2: ...LEDS 6 4 3 Liquid Crystal Display 6 4 4 Keypad 7 4 5 Common Interface 7 5 Real panel 8 5 1 Power Supply 8 5 2 Output Connectors 8 5 3 ASI Input Connector 8 5 4 RS 232 Interface 8 5 5 Ethernet Interfac...

Page 3: ...ion The appropriate servicing authority must be informed For example safety is likely to be impaired if the device fails to perform the intended measurements or shows visible damage WARNINGS Do not us...

Page 4: ...00 S C T D S2 S C T D S2 IP TS DS3 Input Loop through DVB S2 Input DVB C Input DVB T Input PCMCIASlot ASI TS Input Output Audio Embedded SDI Output Ethemet Remote Control BNC Video Output A V Output B...

Page 5: ...he table POWER REQUIREMENT Input voltage 90 260 Vrms auto select Frequency 47 to 63 Hz Power 50 VAmax 30 VAtypical Current 110 V 0 27Aor 240 V 0 125Atypical Caution Table 3 1 Power requirement Be sure...

Page 6: ...s of input signal source which includes IP input QPSK signal input and DVB ASI TS input Liquid Crystal Display The 2 x 20 character Liquid Crystal Display LCD shows all the required information about...

Page 7: ...are used to select between the main menus or sub menus or programs When you stand on the preferred menu and the parameter is active they are also used to change the numerical values Selecting a digit...

Page 8: ...75 Ohm impedance The ASI interface B18 and B19 are used as a redundant output of B8 and B9 out Note the B8 B18 interface could be configured as SDI with Audio embedded Please refer to Chapter 7 3 5 AS...

Page 9: ...rough the Keypad and front panel display when a remote control system is not used Main Menu Turn on the device and wait for 8 to 10 seconds while the device will complete self inspection and configura...

Page 10: ...In refer to section 7 4 6 Optional Function 7 2 2 QPSK COFDM QAM DVB S2 The tuner setting menu is different and exclusive according to DVB S DVB T DVB C DVB S2 tuner is equipped To receive the QPSK C...

Page 11: ...ctivate the LNB 22 kHz control signal to the LNB On or Off Operation Mode select the appropriate operation mode in the menu There are QPSK 1 2 2 3 3 4 4 5 5 6 8 9 9 10 and 8PSK 2 3 3 4 3 5 5 6 8 9 9 1...

Page 12: ...n out board is installed and the TS IP streaming board is set to IP Out Refer to section 7 4 6 Outputs Status CI Decoder ASI ASI2 SDI Mux Filter Ethernet option 7 3 1 Ethernet Figure 7 3 Outputs Menu...

Page 13: ...es detected by this equipment x The programs could be coming from ASI input Tuner TS IP input or the internal CI de encryption block Use the or key to roll up or down between the program names and use...

Page 14: ...to be set Audio PID and Embed Audios Audio PID press the keys to choose the audio PID from 1 4 Embed Audios there are 4 options none one two two and one 7 3 6 Mux Filter Note this Mux or Filter menu i...

Page 15: ...s to roll up the program names where a number in front of the program name indicates the input source 0 xxxxx displays the program name which comes from ASI input 1 xxxxx displays the program name whi...

Page 16: ...ked into one IP stream Therefore each IP stream carries only one program and be delivered to the specified Multicast or Unicast IP address You can configure maximum 6 IPTV channels Multicast Setup use...

Page 17: ...perties Factory Settings Optional Function Machine Type Figure 7 4 System Menu 7 4 1 Local Setup Each This equipment x has an IP address a network sub mask and a gateway These must be set to an approp...

Page 18: ...onfirm or to scrap by pressing EXIT key 7 4 7 Setting Machine Type This setting is reserved for factory setting and you are not allowed to access this menu FAQ 1 Why is there nothing in the LCD Answer...

Page 19: ...bol Rate 2 45 Mb s SCPC or MCPC Rolling Off Coefficient 0 20 or 0 35 FEC 2 3 3 4 5 6 6 7 7 8 Reeds Salomon Decoding 204 188 T 8 I 12 DVB C QAM Demodulation Connector IEC Female 7 8 MHz or F Female 6 M...

Page 20: ...anced FFT mode 2K 8K Guard Interval 1 4 1 8 1 16 1 32 off FEC Code Rate 2 3 3 4 5 6 and 7 8 Ds3 Input Input Impedance 75 Maximum Output Code Rate 44 736 Mbit s Connector BNC Format Unframed Framing ac...

Page 21: ...put 1 optional RGB output 1 RCA CVBS output 1 RCA 1 BNC Audio XRL Balance Output 1 General Operating Temperature 0 45 Storage Temperature 20 70 Humidity 85 Power Supply AC 90V 260V 50Hz 60Hz Dimension...

Reviews: