![Irenis IRD-6000 User Manual Download Page 15](http://html1.mh-extra.com/html/irenis/ird-6000/ird-6000_user-manual_2090191015.webp)
QPSK/IP DEMODULATOR
On
‘Mux List’
sub-menu, on the first row, all encrypted programs are labeled with a
‘$’
sign. All
programs that are being selected to be re-multiplexed are labeled as
‘Pass’, otherwise, the un-selected
programs are labeled as
‘Fobrid’
. Use
<ENTER>-key
to selected or un-selected the program being
shown.
When leaving the
‘Mux List’
sub-menu, a new menu will be shown
‘Confirm changed?’
Press
<ENTER>-key
to validate all programs just be selected to be multiplexed or to scrap by pressing
<EXIT>-key
.
After a few seconds, the multiplexed TS will be generated and delivered to the specified
destination(s).
Filter
Filter Switch:
the internal filter could be switched On/Off. The default value is
‘off’. To activate the filter
function, you should turn on this filter functional block.
Bit Rate:
should be set to a specified value that
doesn’t exceed the Maximum physical limit of the
output medium, otherwise overflow occurs.
Source:
Press the
<ENTER>-key
and use the
< > or < >-key
to roll up or down to select the signal
source of filter function block, there are 4 type of signal source optional:
CI De-encrypted
TUNER
ASI Input
TS/IP input
(only when the TS/IP is set
“IP In”, refer section 7.4.6 for more)
Use
<ENTER>-key
to save or press
<EXIT>-key
to scrap.
Program List:
Press the
<ENTER>-key
to enter
‘Filter List’
sub-menu. It shows all programs carried
by the signal come from the selected source in previous step. The programs could be come from ASI
input, Tuner, TS/IP input or the internal CI de-encryption block. Use
<
> < >-keys
to roll up the
program names, where a number in front of the program name indicates the input source:
0-xxxxx
displays the program name, which comes from ASI input.
1-xxxxx
displays the program name, which comes from TUNER input.
2-xxxxx
displays the program name, which comes from TS/IP input
3-xxxxx
displays the program name which comes from the internal CI functional block.
On
‘Filter List’
sub-menu, all programs that are being selected to be filtered away are labeled as
‘Forbid’
, otherwise, the un-selected programs are labeled as
‘Pass’. Use
<ENTER>-key
to selected or
un-selected the program being shown.
When leaving the
‘Filter List’
sub-menu, a new menu will be shown
‘Confirm changed?’
Press
<ENTER>-key
to validate all programs just be selected to be filtered away or to scrap by pressing
<EXIT>-key
.
After a few seconds, the filtered TS will be generated and delivered to the specified destination(s).
7.3.7 Ethernet
(Note this menu is showed only when the TS/IP streaming is installed and the board is set to
“IP Out”,
refer to section 7.4.6 for how to set up.)
The TS/IP Ethernet connector could also be configured as the output of the transport stream over IP.
The parameters listed below must be set to appropriate values for the network over which the transport
stream over IP is broadcasted.
Stream IP Addr:
Enter the IP address for streaming IP output of the unit.
Stream Netmask:
Enter the network sub mask for the subnet to which the unit is connected for IP
streaming traffic.
Stream Gateway:
Set the gateway for the network to which the unit is connected for IP streaming
traffic.
Stream Mac Address:
factory-set MAC addresses are guaranteed to unique. Therefore you cannot
configure the address.
15