IRENIS EMU-8110 MPEG-2
Encoder User’s Manual
13 / 46
Chapter 3 Operation
This IRENIS EMU-8110 Encoder’s front panel is user operating interface. Before operating,
user can decide whether directly use the default setting or customize the input and output
parameters setting. The detail operations go as follows:
Keyboard Function Description:
ENTER:
Activating the parameters which need modifications, or confirming the change after
modification.
MENU:
To cancel presently entered value, resume previous setting and return to previous
menu.
LEFT/RIGHT:
To move the “
►
” to choose or set the parameters.
UP/DOWN:
To modify activated parameter or page up/down when parameter is
inactivated.
LOCK:
To
Lock the screen / cancel the lock state. After pressing lock key, the system will
question the users to save present setting or not. If not, the LCD will display the current
configuration state.
At the “Factory Configuration” page, user can press “
ENTER
” key to restore the factory
default configuration.
3.1 Initializing
After powering on the device
,
it will take a few seconds to initialize the system, and then the
LCD will show the device name and output real-time bit-rate in the first row, while the 8
channels’ respective serial number, encoding system (
P
: PAL;
N
: NTSC) and input real-time
encoding bit-rate in the second row in turn. It shows as below:
8 in 1 Encoder 23.485 Mbps
1P 02.94M 2N 02.73M 3P 02.92M 4N 02.90M
3.2 General Setting