The Motor Diagnostics option is an extraordinary feature that can allow precise adjustment of the
motor maximum output force. When Motor Diagnostics are turned on, upon exiting the menus,
the display will reflect the motor amperage high and voltage low in real time when the motor is
running. At the end of the cycle, the highest amperage and lowest voltage that was last detected
will be displayed. By using this feature, proper adjustment to the open and close force settings
can be obtained. Be sure to turn the diagnostic features off when not required
)
Motor Drive Menu
•
Operator Handing = Left or Right (determines the gate travel opening direction)
•
Operator Type = Single (Single Operator), Master, Slave
•
Open Force = user selectable amperage level from 00.1 to 20.0
Default=13.0 amps
•
Close Force = user selectable amperage level from 00.1 to 20.0
Default=13.0 amps
•
Force Delay=
0.5
(
recommended
) this is the selectable time from .5 seconds up to 2
seconds in which the amperage may be reached or exceeded before the gate reverses due
to a motor open or close force alarm
•
Max Speed = user selectable maximum motor speed from 10% to 100%
•
Min Speed = user selectable minimum motor speed from 10% to 90%
•
Open Delay = sets the desired open delay from 0.0 seconds to 5.0 seconds
•
Close Delay = sets the desired close delay from 0.0 seconds to 5.0 seconds
•
Acceleration Step Size = sets the rate of motor acceleration- the higher the rate, the faster
the ramp up to the maximum set speed
•
Deceleration Step Size = sets the rate of motor deceleration- the higher the rate, the faster
the ramp down to the minimum set speed
Exit the sub-menu
Digi / Tach Learning – Enter if Applicable
(This is the menu that will allow you set the value of the soft stop in a percentage value.
o
Close limit is _ _ _ _ counts
o
Open Limit is _ _ _ _ counts
o
Open Slow Down at _ _% (this is the percent of gate travel that the soft stop would
begin) [default is 86%]
o
Close Slow Down at _ _% (this is the percent of gate travel that the soft stop would
begin) [default is 86%]
Exit the sub-menu
22