background image

(

The Motor Diagnostics option is an extraordinary feature that can allow precise adjustment of the 

motor maximum output force.  When Motor Diagnostics are turned on, upon exiting the menus, 
the display will reflect the motor amperage high and voltage low in real time when the motor is 
running.  At the end of the cycle, the highest amperage and lowest voltage that was last detected 
will be displayed.  By using this feature, proper adjustment to the open and close force settings 
can be obtained.  Be sure to turn the diagnostic features off when not required

Motor Drive Menu 

Operator Handing = Left or Right (determines the gate travel opening direction) 

Operator Type = Single (Single Operator), Master, Slave 

Open Force = user selectable amperage level from 00.1 to 20.0 

Default=13.0 amps 

Close Force = user selectable amperage level from 00.1 to 20.0 

Default=13.0 amps 

Force Delay= 

0.5

 (

recommended

) this is the selectable time from .5 seconds up to 2 

seconds in which the amperage may be reached or exceeded before the gate reverses due 
to a motor open or close force alarm 

Max Speed = user selectable maximum motor speed from 10% to 100% 

Min Speed = user selectable minimum motor speed from 10% to 90%  

Open Delay = sets the desired open delay from 0.0 seconds to 5.0 seconds 

Close Delay = sets the desired close delay from 0.0 seconds to 5.0 seconds 

Acceleration Step Size = sets the rate of motor acceleration- the higher the rate, the faster 
the ramp up to the maximum set speed 

Deceleration Step Size = sets the rate of motor deceleration- the higher the rate, the faster 
the ramp down to the minimum set speed 

Exit the sub-menu 

Digi / Tach Learning – Enter if Applicable  

 

(This is the menu that will allow you set the value of the soft stop in a percentage value. 

 

o

Close limit is _ _ _ _ counts 

o

Open Limit is _ _ _ _ counts 

o

Open Slow Down at _ _% (this is the percent of gate travel that the soft stop would 
begin) [default is 86%] 

o

Close Slow Down at _ _% (this is the percent of gate travel that the soft stop would 
begin) [default is 86%] 

Exit the sub-menu 

 

22

Summary of Contents for IntelliSlide X6

Page 1: ...IntelliSlide X6 Installation And Instruction Manual UL 325 991 Compliant REV C 04 2020 www iqgatesystems com 1 801 455 7961 ...

Page 2: ...to wholesale customers who buy direct from IQ Gate Systems or through IQ Gate Systems normal distribution channels This warranty also only covers and is extended to products that are manufactured by IQ Gate Systems IQ Gate Systems does not warrant any products in any way to the end user consumer Consumers must obtain warranty information from the selling dealer and or installer as to the nature of...

Page 3: ...from the end user consumer will be referred to the consumer s selling dealer and or installer This IQ Gate Systems Limited Warranty is in lieu of all other warranties express or implied and all IQ Gate Systems warranties are subject but not limited to the following conditions 1 The products must be properly re installed as specified and maintained or used as intended 2 Cause of repaired product fa...

Page 4: ...at is capable of operating gates up to 45 in overall length or up to 1500 lbs in weight Be sure to inspect gate hardware and verify that the gate rolls smoothly Replace gate hardware as needed to insure that the operator doesn t require excessive force to operate the gate 4 ...

Page 5: ...5 ...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...e required operable amounts to compensate for a damaged gate 5 For gate operators utilizing Type D protection The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving The placard be placed adjacent to the controls An automatic closing device such as a timer loop sensor or similar device shall not be employed No other activation device shall ...

Page 10: ... at the bottom edge of a vehicular vertical lift gate One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage A wireless contact sensor such as one that transmits radio frequency RF si...

Page 11: ...11 ...

Page 12: ... method of supply Depending on soil conditions set the concrete pad at least 2 feet in the ground with an abundance of concrete Check and conform to local codes Install the gate with the incline of the road in mind For proper operation the gate must slide back and forth at a level plane For Master Slave Applications It is recommended that a total linear footage distance of 120 feet is not exceeded...

Page 13: ...e the chain is attached it needs to be tightened Be careful not to over tighten the chain Proper adjustment is 1 2 of sag for every 10 feet of chain After the chain has been installed the magnetic limits need to be installed To do so switch the MOTOR SWITCH to the MANUAL position Push the gate in the open direction until the gate reaches the full open limit Attach the Magnetic Limit Block to the c...

Page 14: ...e loop detector slots are available for use as a OPEN REVERSE CLOSE RESET and DISABLE The RESET detector will provide a close contact to the controller after the the loop has been activated and then deactivated This is a good option for Anti Tailgating and Quick Close applications as it will override the Close Timer The DISABLE option will allow the detector to still detect and consume power but n...

Page 15: ...15 ...

Page 16: ...16 ...

Page 17: ... Be sure to keep the loops at least 5 from the gate 17 ...

Page 18: ...f the LCD display The 8 menus consist of the following Adjust the Clock Adjust Time Settings Auxiliary Settings Maintenance Menu Motor Drive Menu Digi Tach Learning Error and Fault Log Password Protected To enter any of the menus from the Home Screen the current Date and Time is displayed on the Home Screen simply press the GREEN button Adjust the Clock will be displayed At this point you have ent...

Page 19: ...ime and then display what days you would like the timer to function If a day is undesired move the cursor under that day and press the programming knob to erase that day from the program Then scroll clockwise and set the days and time for the auto close Here is an example of the 7 day open timer 7Day Security Timer Completely Off Off to next next on program On The security timer has 2 available ti...

Page 20: ...y activation on the close limit o Hold on Open Limit latches the relay on the open limit o Hold on Close Limit latches the relay on the close limit o Pulse on Motor Open a 2 second relay activation when gate is opening o Pulse on Motor Close a 2 second relay activation when gate is closing o Hold on Motor Open latches the relay when gate is opening o Hold on Motor Close latches the relay when gate...

Page 21: ...ate will continue to function regardless of low power Fire the gate will only open from a FIRE input Alarm Relay Pulsed or Continuous output Motion Warning Type 3 Sec Pre Warn Activates the alarm relay for 3 seconds before motion Motion Warning Activates the alarm relay 3 seconds before motion as well as during gate motion Off no audible notification of gate motion Limit Secure Off or On this is f...

Page 22: ... from 5 seconds up to 2 seconds in which the amperage may be reached or exceeded before the gate reverses due to a motor open or close force alarm Max Speed user selectable maximum motor speed from 10 to 100 Min Speed user selectable minimum motor speed from 10 to 90 Open Delay sets the desired open delay from 0 0 seconds to 5 0 seconds Close Delay sets the desired close delay from 0 0 seconds to ...

Page 23: ...ations as well as the time and date that they occurred and what the recorded temperature was at that time You may navigate back through the log using the YELLOW button and view the events as they occurred with the date and time displayed To exit the sub menu just press the GREEN button 23 Error and Fault Log ...

Page 24: ...he Fault Error menu 24 Close Timer On Open Detected Open Close Detected Reverse Detected Open Lim Secure Open Limit Secured Option 1 2 Input Term Open Limit Close Limit Close Detected UL 325 Alarm UL 325 Reset Mon Edge Detected FIRE Input Maint Request Open Force Open Force Exceeded ENCODER err Close Lim Secure Close Limit Secured Secured Input Secured Timer input Stop Detected Max Run Expired Low...

Page 25: ...UI Comm DS 7 M S Comm DS 6 M S Comm DS 22 DRIVE Motor activity status GREEN DS 16 TACH YELLOW DS 17 CLOSE Limit RED DS 18 OPEN Limit GREEN DS 15 AC DC Supply POWER GREEN DS 1 Processor GREEN Every 6 months to 1 year a qualified service technician should inspect test and adjust the inherent safety sensor as well as the batteries belts chains and grease the bearings Also all bolts and nuts should be...

Page 26: ... Display and all LED s Check if security timer is active and what inputs are being secured Verify limit position reset limit Check battery voltage and F4 Fuse Remove stop signal input Remove close signal input Remove abort signal input Check Open Photoeye or edge for activation failure Check both board fuses Check and remove shorts or over voltages Survey the area surrounding the gate when clear a...

Page 27: ...ent reset loop detector check the loop integrity Check for a vehicle present reset loop detector check the loop integrity Check for a vehicle present reset loop detector check the loop integrity Remove contact from input Remove contact from input Remove contact from input and press the master reset button Check the LED of the Tach input terminal as well as the Tach Count at the bottom right of the...

Page 28: ...Gate reverses when closing Check all of the above causes Check the Error and Fault Log Check the Display and all LED s Check all of the above solutions 28 ...

Page 29: ...29 ...

Page 30: ...30 ...

Reviews: