![IQ Gate Systems IntelliSlide X6 Installation And Instruction Manual Download Page 21](http://html1.mh-extra.com/html/iq-gate-systems/intellislide-x6/intellislide-x6_installation-and-instruction-manual_2089479021.webp)
•
Open/Close Terminal = Open-Stop-Close, Open Only, Partial Open
•
Partial Open Timed Run = 03 Seconds (this is the programmable amount of time that the
gate can run when a partial open signal is given through the Radio Terminal)
•
Lock Relay – 2 seconds, 7 seconds, Full Cycle
Exit the sub-menu
Maintenance Menu
•
Main Power Fail = Hold Open or Normal (default is NORMAL)
•
Maintenance Request in = Cycles or Days
•
Maintenance Request after = _ _ Cycles or _ _ Days
•
Current _ _ _ _ _ _ Cycles/Days – Enter to reset (pressing the programming knob to enter
will erase and reset the current maintenance count)
•
Total Operator Cycle = M1 00,000,000 (this is displaying the total accumulated cycles and
is non-resettable)
•
Low Power Function =
Hold Open – the gate will hold open until battery is above 75% full
Normal – the gate will continue to function regardless of low power
Fire – the gate will only open from a FIRE input
•
Alarm Relay = Pulsed or Continuous output
•
Motion Warning Type =
3 Sec Pre-Warn – Activates the alarm relay for 3 seconds before motion
Motion Warning – Activates the alarm relay 3 seconds before motion as well as during gate motion
Off – no audible notification of gate motion
•
Limit Secure = Off or On (this is fail-secure option recommended for use in the IQ-5000
only)
•
Input Contacts = Momentary or Constant (affects the OPEN and CLOSE inputs) should be
set on Momentary
•
Activate De-Icing at Temp: 37 F = (user selectable temperature) this temperature setting is
used to activate the De-Icing mode if activated. It can also be used to energize the output
relays if they have been selected to activate on a temperature selection
•
Motor Diagnostics Off or On (turns off or on the motor diagnostics) (
see below
)
•
Temperature Cal Display = (allows the thermostat to be calibrated accurately)
Exit the sub-menu
21