30
6
3x230V R5
3x400V R5
4,2kw 3x1,4kw
LC1D0901
LC1D0901
6kw 3x2kw
LC1D0901
LC1D0901
9kw 3x3kw
LC1D1810
LC1D0901
12kw 3x4kw
------
------
LC1D0901
1/2
1/2
1/3
12kw 3x2kw
LC1D253
LC1D0901
3x2kw
15kw 3x2kw
LC1D253
LC1D1810
3x3kw
18kw 3x3kw
LC1D323
LC1D1810
3x3kw
21kw 3x3kw
------
------
LC1D1810
3x4kw
------ ------
LC1D1810
24kw 3x4kw
------
------
LC1D1810
3x4kw
------ ------
LC1D1810
Technical remarks
Probe
Window
Heating
B = Black
Br = Brown
Gy = Grey
Bu = Blue
R = Red
W = White
PU = Purple W/B = White/black
Remark:
Other executions are available as options.
The tilt switch is mounted on the solid part of the machine. There is a window
around the probe of the tilt switch that is mounted on the movable part of the
machine.
When the machine goes out of balance by overloading or uneven distribution
of the linen, the tilt switch will interrupt this action to prevent damage to the
machine.
Important
To guarantee good functioning, the probe should be centered horizontally
and vertically at 1/3 from the bottom of the tilt window (when machine
drum is empty).
Tilt switch
Heating
R5
3kw
LC1D0901
1 AC
3 AC
Internal connections of the electrical