11
230V 1AC 230V 3AC 4000V 3AC + N
3kW
16A
---
---
4,2 kW
---
16 A
16 A
6 kW
---
16 A
16 A
9 kW
---
25 A
16 A
12 kW
---
40 A
20 A
15 Kw
---
50 A
25 A
18 Kw
---
50 A
32 A
21
Kw
---
---- 40
A
24
Kw
---
---- 40
A
Remove the cover plate at the back of the machine. (See dimensions (E).
Connect the power cable to the connectors.
Machine without electric heating
Connect 230 V single phase (1AC) to the connectors “
N
” and “
L1
”.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
Machine with electric heating
230V 1AC
230V 1 phase (1AC) should be connected to the connectors “
L1
”-
“
N
”.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
230V 3AC
230V 3 phase (3AC) should be connected to the connectors
“
L1,L2,L3
”.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
4000V 3AC + N
400V 3 phase (3AC + N) has to be connected to the connectors
“L1,L2,L3”
,
the blue neutral to the “N” connector
.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
Machine with steam heating or boiler fed machines without ad-
ditional electrical heating
machine with electrical heating
230V 1AC
16 A
3
Power of the breaker plugs:
Electrical Connection
Summary of Contents for HC100