background image

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR 

IPS121

 

7

If "GSM 3G DECT  WF BT" submenu is selected in main MENU you will 

see  the  submenu  which  allows  work  with  signals  imitating  data  transmission 
standards:  "GSM"  -  GSM900,  "3G"  -  Third  generation  of  mobile 
telecommunications, "DECT" - Digital Enhanced Cordless Telecommunications as 

well as data transmission standards in 2.4GHz frequency range: "WF" - Wireless 
local area network (Wi-Fi) and "BT" - Bluetooth. (Pic. 4) 

It  is  possible  to  select  a  standard  required  to  be  imitated  as  well  as 

output power. 

Carrier frequency, band of signal and time parameters of radio impulse 

are imitated. 

If "LF/MF.01-120kHz" submenu is selected in main MENU, you will see 

the  submenu  which  allows  work  with  acoustic  and  ultrasound  signals  in  0.01-

120kHz  frequency  range  outputted  through  "LF"  socket.  It  also  turns  magnetic 
field emitter on. Position of this emitter is marked on the front panel as: "MF". In 
this  case  stray  emission  of  radio-electronic  devices  is  imitated  (cell  phones, 

recorders etc.). (Pic. 5) 

"LF" (TRS 3.5”) socket is an output for low frequency amplifier and 

intended  for  speakers  (Pic.  6) 

There  are  three  options  for  carrier 

frequency selection:

 

Random selection of frequency

Frequencies corresponding to the octave filter.

Frequencies corresponding to third octave filter.

With  selection  of  item  "Modulation  OFF"  it  is  possible  to  select

modulation of carrier signal: FM, AM or PWM. 

If AM or FM is selected, "Frequency" option will appear allowing selection of modulation signal 

frequency  (for  AM  and  FM  modulation).  "Deviation"  option  will  appear  for  FM  allowing  selection  of 

highest deviation for modulated signal frequency from value of its carrier frequency

 

If  PWM  is  selected  two  options  will  appear:  "Frequency"  allowing  selection  of  frequency  of 

impulse and "Ratio" allowing selection of interval between impulses. 

Power is changed in % of maximum power. 

If "RJ-45 .01-20000kHz" submenu is selected in main MENU, you will 

see  the  submenu  which  allows  work  with  signals  in  0.01-20000kHz  range 

outputted  through  "RJ-45"  socket  to  "4-5"  pair  (Pic.  7).  Pair  "3-6"  used  as 
device's  “ground”  which  allows  for  asymmetrical  connection  to  the  line.  Cable 

"3/RJ-45"  is  used  for  such  connection.  Black  wires  are  connected  to  the 
“ground” and red to the "4-5" pair. 

With  selection  of  line  "Modulation  OFF"  it  is  possible  to  select 

modulation of carrier signal: FM, AM or PWM. 

If  AM  or  FM  is  selected  "Frequency"  option  will  appear  allowing 

selection of modulation signal frequency (for AM and FM modulation). "Deviation" option will appear for 
FM  allowing  selection  of  highest  deviation  for  modulated  signal  frequency  from 
value of its carrier frequency

 

If  PWM  is  selected  two  options  will  appear:  "Frequency"  allowing  selection  of  frequency  of 

impulse and "Ratio" allowing selection of interval between impulses. 

Picture 3 

Picture 4

 

Picture 5

 

Picture 6

Summary of Contents for IPS121

Page 1: ...TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121 1 IPS SIGNAL IMITATOR TECHNICAL DESCRIPTION AND OPERATING MANUAL ...

Page 2: ...AL DESCRIPTION 4 1 1 Purpose of the device and main capabilities 4 1 2 Contents 4 1 3 Main module 4 1 4 Power supply 5 1 5 Operation modes 6 2 RESTRICTIONS AND RECOMMENDATIONS 9 3 TECHNICAL SPECIFICATIONS 9 4 LIFE TIME AND MANUFACTURER S WARRANTY 12 5 CERTIFICATE OF ACCEPTANCE 12 ...

Page 3: ...STRUCTIONS FOR IPS121 3 Introduction Before starting your work with IPS121 carefully read this instruction and save it for further use as a handbook Any information in this manual can be changed fully or partially without further notice ...

Page 4: ...cy Sound and ultrasound signals with user defined frequency or with frequency values corresponding to octave and third octave filters and direct connection of speakers to the IPS121 output socket Low frequency magnetic field Imitation of nonlinear transition in wire lines 1 2 IPS121 Contents 1 Main module 2 HF antenna 3 RJ 45 cable 4 220V cable 5 3 RJ 45 cable 6 Power supply charger 5V 1A 7 Techni...

Page 5: ...kHz range ________________________________________________________________________ 1 4 IPS121 Power supply Battery status icon is located in upper right corner of main menu screen Fully colored icon corresponds to fully charged battery uncolored crossed with line discharged 1 4 1 Battery charging To charge internal battery connect power supply State of power switch has no effect on charging Chargi...

Page 6: ...1 6 GHz range outputted through HF SHF socket intended for RF antenna Setting altering can be achieved using ROTARY KNOB with step selected in SETTING submenu Default value is 10 MHz If Modulation OFF is selected it will change carrier signal modulation type AM or FM as well as FHSS Frequency Hopping Spread Spectrum DSSS Direct Sequence Spread Spectrum and PULSE If AM or FM is selected Frequency o...

Page 7: ...item Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will appear allowing selection of modulation signal frequency for AM and FM modulation Deviation option will appear for FM allowing selection of highest deviation for modulated signal frequency from value of its carrier frequency If PWM is selected two options will appear...

Page 8: ...f impulse and Ratio allowing selection of interval between impulses Power is changed in of maximum power If IR 940nm submenu is selected in main MENU you will see the submenu which allows work with IR emitter located on the front panel Pic 1 Pos 7 With selection of line Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will a...

Page 9: ...ONS HF SHF socket Frequency range MHz 100 6000 Frequency tuning step kHz 10 100 1000 10000 100000 Signal level dBm 42 14 Stray harmonics dBm 100 200MHz 15 200 700 1100 1500MHz 45 800 1000 1600 6000MHz 30 Signal Sinusoidal DSSS FHSS PULSE Modulation AM FM Data transmission standards imitation GSM 3G DECT WLAN BLUETOOTH Modulation frequency kHz 0 5 1 1 5 15 АМ depth 70 FM Deviation kHz 30 100 300 60...

Page 10: ...quency range kHz 30 20000 Maximum signal amplitude V 3 5 Maximum input voltage V 380 Modulation FM DSSS Modulation frequency kHz 0 5 1 1 5 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 10 40 и 100 PWM Duty cycle 1 5 10 IR emitter Wave length nm 940 Subcarrier frequency range kHz 0 01 5000 Stray harmonics dBm 30 Output power mW 0 5 Modulation AM FM DSSS Modulation frequency kHz 0 5 ...

Page 11: ... 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 25000 31500 40000 50000 63000 80000 100000 Nonlinear distortion no more than 1 Modulation AM FM DSSS Modulation frequency kHz 0 5 1 1 5 15 АМ depth 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 20 PWM Duty cycle 1 5 10 Magnetic field emitter MF Equivalen...

Page 12: ...ill follow exploitation transportation and storage regulations stated in this instruction Warranty period one year from the day of delivery to the customer 4 2 2 During warranty period manufacturer will provide free of charge repairs as long as consumer will follow exploitation transportation and storage regulations stated in this instruction 5 CERTIFICATE OF ACCEPTANCE IPS121 device Certified ___...

Page 13: ...___ Manufactured ________________ Manufacturer s stamp Sold ___________________________________ Date ________ vendor s identification Salesman __________________ Vendor s stamp signature CARD STUB 1 For warranty repair maintenance IPS121 Serial ______________ Date ________________ Executor _______________________________ Family name signature ...

Reviews: