2 RESTRICTIONS AND RECOMMENDATIONS 

2.1 Transport and store 

IPS121

 in standard package. 

For  prolonged  storing  you  should  use  closed,  warm  compartment  with  temperature  10-35C  and 

humidity no more than 80%. 

Transport with caution and try to avoid physical interference with standard package. 

2.2  After  prolonged  (more  than  4  hours)  stay  of  the  device  in  cold  (less  than  -5C)  it  only  should  be 

turned on if there is no evidence of condensate on the device. 
2.3 Do not expose LCD display to the direct sunlight. 

3 TECHNICAL SPECIFICATIONS

"HF-SHF" socket 

Frequency range, MHz   

100-6000 

Frequency-tuning step, kHz 

10, 100, 1000, 10000, 100000 

Signal level, dBm 

-42 – +14* 

Stray harmonics, dBm

 

100-200MHz 

-15 

200-700, 1100-1500MHz 

-45 

800-1000, 1600-6000MHz 

-30 

Signal   

Sinusoidal, DSSS ,FHSS, PULSE 

Modulation 

AM, FM 

Data transmission standards imitation    

GSM, 3G, DECT, WLAN, BLUETOOTH 

Modulation frequency, kHz 

0.5, 1, 1, 5, 15 

АМ depth, %   

70 

FM

 

Deviation, kHz  

30, 100, 300, 600 

Nonlinear distortion of modulating signal, no more than, % 

15 

FHSS

 Bandwidth of Hopping

, MHz  

1, 6, 10, 20, 50, 100

 

FHSS

 Number of Hopping Channels

   

25, 50, 125, 250

 

FHSS Frequency of hopping, Hz  

1, 2, 4, 8

 

DSSS Bandwidth, MHz   

0.3, 0.5, 1, 2, 4 

PULSE Signal transmission time, sec 

0.0001- 99 

PULSE

 

Signal accumulation time, sec 

0.01-5999  

*Variation range depends on signal frequency and selected standard

Summary of Contents for IPS121

Page 1: ...TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121 1 IPS SIGNAL IMITATOR TECHNICAL DESCRIPTION AND OPERATING MANUAL ...

Page 2: ...AL DESCRIPTION 4 1 1 Purpose of the device and main capabilities 4 1 2 Contents 4 1 3 Main module 4 1 4 Power supply 5 1 5 Operation modes 6 2 RESTRICTIONS AND RECOMMENDATIONS 9 3 TECHNICAL SPECIFICATIONS 9 4 LIFE TIME AND MANUFACTURER S WARRANTY 12 5 CERTIFICATE OF ACCEPTANCE 12 ...

Page 3: ...STRUCTIONS FOR IPS121 3 Introduction Before starting your work with IPS121 carefully read this instruction and save it for further use as a handbook Any information in this manual can be changed fully or partially without further notice ...

Page 4: ...cy Sound and ultrasound signals with user defined frequency or with frequency values corresponding to octave and third octave filters and direct connection of speakers to the IPS121 output socket Low frequency magnetic field Imitation of nonlinear transition in wire lines 1 2 IPS121 Contents 1 Main module 2 HF antenna 3 RJ 45 cable 4 220V cable 5 3 RJ 45 cable 6 Power supply charger 5V 1A 7 Techni...

Page 5: ...kHz range ________________________________________________________________________ 1 4 IPS121 Power supply Battery status icon is located in upper right corner of main menu screen Fully colored icon corresponds to fully charged battery uncolored crossed with line discharged 1 4 1 Battery charging To charge internal battery connect power supply State of power switch has no effect on charging Chargi...

Page 6: ...1 6 GHz range outputted through HF SHF socket intended for RF antenna Setting altering can be achieved using ROTARY KNOB with step selected in SETTING submenu Default value is 10 MHz If Modulation OFF is selected it will change carrier signal modulation type AM or FM as well as FHSS Frequency Hopping Spread Spectrum DSSS Direct Sequence Spread Spectrum and PULSE If AM or FM is selected Frequency o...

Page 7: ...item Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will appear allowing selection of modulation signal frequency for AM and FM modulation Deviation option will appear for FM allowing selection of highest deviation for modulated signal frequency from value of its carrier frequency If PWM is selected two options will appear...

Page 8: ...f impulse and Ratio allowing selection of interval between impulses Power is changed in of maximum power If IR 940nm submenu is selected in main MENU you will see the submenu which allows work with IR emitter located on the front panel Pic 1 Pos 7 With selection of line Modulation OFF it is possible to select modulation of carrier signal FM AM or PWM If AM or FM is selected Frequency option will a...

Page 9: ...ONS HF SHF socket Frequency range MHz 100 6000 Frequency tuning step kHz 10 100 1000 10000 100000 Signal level dBm 42 14 Stray harmonics dBm 100 200MHz 15 200 700 1100 1500MHz 45 800 1000 1600 6000MHz 30 Signal Sinusoidal DSSS FHSS PULSE Modulation AM FM Data transmission standards imitation GSM 3G DECT WLAN BLUETOOTH Modulation frequency kHz 0 5 1 1 5 15 АМ depth 70 FM Deviation kHz 30 100 300 60...

Page 10: ...quency range kHz 30 20000 Maximum signal amplitude V 3 5 Maximum input voltage V 380 Modulation FM DSSS Modulation frequency kHz 0 5 1 1 5 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 10 40 и 100 PWM Duty cycle 1 5 10 IR emitter Wave length nm 940 Subcarrier frequency range kHz 0 01 5000 Stray harmonics dBm 30 Output power mW 0 5 Modulation AM FM DSSS Modulation frequency kHz 0 5 ...

Page 11: ... 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 25000 31500 40000 50000 63000 80000 100000 Nonlinear distortion no more than 1 Modulation AM FM DSSS Modulation frequency kHz 0 5 1 1 5 15 АМ depth 15 FM Deviation kHz 5 20 100 300 Frequency of PWM signal Hz 1 20 PWM Duty cycle 1 5 10 Magnetic field emitter MF Equivalen...

Page 12: ...ill follow exploitation transportation and storage regulations stated in this instruction Warranty period one year from the day of delivery to the customer 4 2 2 During warranty period manufacturer will provide free of charge repairs as long as consumer will follow exploitation transportation and storage regulations stated in this instruction 5 CERTIFICATE OF ACCEPTANCE IPS121 device Certified ___...

Page 13: ...___ Manufactured ________________ Manufacturer s stamp Sold ___________________________________ Date ________ vendor s identification Salesman __________________ Vendor s stamp signature CARD STUB 1 For warranty repair maintenance IPS121 Serial ______________ Date ________________ Executor _______________________________ Family name signature ...

Reviews: