Ytterbium Fiber Laser, Model YLR-200-AC
IPG Laser GmbH, 2009
Proprietary Information. All rights reserved
Rev. Date 08-12-2009
18
15
Modu
24 VDC Input.
16
Modulation -
Return for signal on pin 15.
18
Emission Enable
24VDC Input. Edge
sensitive. To be used to
activate the emission when
operating in REMOTE
regime.
20
Common
Return for signals on pins
18, 23, 24
23
Power Supply Active
24 VDC 100mA Output. If
high indicates that the
internal main power supply
is active.
24
Emission On
24VDC 100mA Output. If
high indicates in REMOTE
control regime that the
emission is enabled.
13,17, 19,
21, 22
Reserved
Should be disconnected
from each other and from
other pins of the connector.
9
IDENTIFICATION LABEL
Contains information about the device
10
1FU, 2FU
Electrical fuses 15 A.
11
AC LINE INPUT
100-240 VAC, 50/60 Hz
12
OPTICAL OUTPUT
Optical fiber cable with output termination.
*
)
To have a possibility of the internal main power supply activation it is necessary that pin1 is connected with
pin4 and pin2 is connected with pin3. Otherwise, the internal main power supply is switched off and the
emission cannot be turned on. Once any of the pairs of the mentioned above contacts has been opened it is
impossible to switch the lasers power supply on till the second pair is opened and then both pairs are
shortened.