background image

Ion Technologies Sumpro

®

Battery Back-Up

OPERATION MANUAL

Dated: 08/18/2017

Document Name: SUMPRO_100_OM

Page 9 of 12

www.ionproducts.net

LCD Display

Description

Remedy

7

Battery Voltage

26.7 V

Battery voltage when batteries are 

deemed present.

Normal

8

Battery Capacity

91%

Battery capacity when batteries 

are deemed present.  Capacity is 

calculated based on battery voltage 

alone.  While inverting, the battery 

capacity can drop 15-20% when 

load is connected and running.

Normal

Alarm & Fault Code LCD Displays

LCD Display

Description

Remedy

1

Batteries Not

Installed

The unit will detect that batteries are 

connected by installing fully charged 

batteries  or  if  it  draws  sufficient 

current while charging. 

Install batteries of the 

same age, make and 

model. Once the unit 

detects that batteries 

are present, the unit will 

always assume batteries 

are connected unless 

the unit is completely 

powered off.

2

AC Input Voltage

LOST

The unit has detected a loss of 

AC power from the utility and has 

switched to DC mode.

The unit must detect 

good AC voltage before 

switching back to AC 

mode.

3

AC Input Voltage

UNDERVOLTAGE

The unit has detected an 

undervoltage condition and has 

switched to DC mode.

The unit must detect 

good AC voltage before 

switching back to AC 

mode.

4

AC Input Voltage

OVERVOLTAGE

The unit has detected an overvoltage 

condition and has switched to DC 

mode.

The unit must detect 

good AC voltage before 

switching back to AC 

mode.

5

Invert Lock OFF:

10 S

The unit has suspended DC mode 

because of a fault condition.  The 

display shows time left before DC 

mode will resume.

DC mode will resume 

after the time expires.

6

Charge Lock OFF:

10 S

The unit has suspended battery 

charging because of a fault condition. 

The display shows time left before 

charging start timer can begin.

Battery charging will 

resume after the timer 

expires.

Below are the most common alarms and faults.  For a complete list of LCD display alarms and faults, please refer 

to the separate Sumpro

®

 Troubleshooting Guide on our web site.

Summary of Contents for Sumpro

Page 1: ...the grounding prong from the power cord 3 Do not smoke use sparkable electrical devices or open flame when working on this unit 4 Do not install Unit in locations classified as hazardous per N E C AN...

Page 2: ...ilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive and corrosive The following procedures should be observed a If electrolyte contacts the skin wash it off immediat...

Page 3: ...nd to keep the unit off the floor A dedicated 15A receptacle circuit is recommended 3 Assembly Set the battery box in place making sure that the openings will be facing the back of the head unit Once...

Page 4: ...18 2017 Document Name SUMPRO_100_OM Page 4 of 12 www ionproducts net A Figure A POSITIVE BATTERY LEAD AND TERMINAL NEGATIVE BATTERY LEAD AND TERMINAL ALTERNATIVE DC INPUT ACCESS COVER BATTERY BOX MOUN...

Page 5: ...tructions in the controller manual The controller will be plugged into the Sumpro instead of the wall outlet If connecting a home alarm system to the Sumpro make the connection to the 6P6C RJ11 jack l...

Page 6: ...ence has NOT been pressed b Solid when unit is running off inverter and silence has been pressed c Off when unit is operating off of AC Line 3 Alarm Red LED a Blinks when alarm condition occurs and si...

Page 7: ...as been applied to the wrong voltage 9 Any labels or cord tags have been removed Replacing Batteries Wear full eye protection and protective clothing When replacing the batteries use the same type and...

Page 8: ...rews are tightened to 75 pound inches 4 Check fuse link for blown fuses The system is stuck in a fault that won t clear 1 Reboot the system a While in AC mode disconnect the positive red wire from the...

Page 9: ...nput Voltage LOST The unit has detected a loss of AC power from the utility and has switched to DC mode The unit must detect good AC voltage before switching back to AC mode 3 AC Input Voltage UNDERVO...

Page 10: ...into a fault condition and has suspended all operations The display shows time left before operations can begin again Normal operation will resume after the timer expires 9 Sumpro Status INVERT SUSPEN...

Page 11: ...t and send back to Metropolitan Ind Warranty Department P O Box 7266 Romeoville IL 60446 Or to register online go to www ionproducts net Sumpro Warranty Registration Card To register your purchase ple...

Page 12: ...ect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until...

Reviews: