Ion Technologies Sumpro

®

Battery Back-Up

OPERATION MANUAL

Dated: 08/18/2017

Document Name: SUMPRO_100_OM

Page 10 of 12

www.ionproducts.net

LCD Display

Description

Remedy

7

Cool Lock OFF:

10 S

The unit has suspended battery 

charging because it needs to cool 

off for a period of time.  The display 

shows time left before charging start 

timer can begin.

Battery charging will 

resume after the timer 

expires.

8

Fault Lock OFF:

10 S

The unit has entered into a fault 

condition and has suspended all 

operations. The display shows time 

left before operations can begin 

again.

Normal operation will 

resume after the timer 

expires.

9

Sumpro Status

INVERT SUSPENDED

The unit has stopped DC mode due 

to a fault condition. Subsequent 

screens will state info regarding 

suspension.

The underlying fault 

condition must clear and 

the related lock timer must 

elapse.

10

Sumpro Status

FAULTED

The unit has detected a fault 

condition and has stopped all 

operations until condition clears 

and/or necessary time has elapsed 

since fault.

The underlying fault 

condition must clear and 

the related lock timer must 

elapse.

Summary of Contents for Sumpro

Page 1: ...the grounding prong from the power cord 3 Do not smoke use sparkable electrical devices or open flame when working on this unit 4 Do not install Unit in locations classified as hazardous per N E C AN...

Page 2: ...ilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive and corrosive The following procedures should be observed a If electrolyte contacts the skin wash it off immediat...

Page 3: ...nd to keep the unit off the floor A dedicated 15A receptacle circuit is recommended 3 Assembly Set the battery box in place making sure that the openings will be facing the back of the head unit Once...

Page 4: ...18 2017 Document Name SUMPRO_100_OM Page 4 of 12 www ionproducts net A Figure A POSITIVE BATTERY LEAD AND TERMINAL NEGATIVE BATTERY LEAD AND TERMINAL ALTERNATIVE DC INPUT ACCESS COVER BATTERY BOX MOUN...

Page 5: ...tructions in the controller manual The controller will be plugged into the Sumpro instead of the wall outlet If connecting a home alarm system to the Sumpro make the connection to the 6P6C RJ11 jack l...

Page 6: ...ence has NOT been pressed b Solid when unit is running off inverter and silence has been pressed c Off when unit is operating off of AC Line 3 Alarm Red LED a Blinks when alarm condition occurs and si...

Page 7: ...as been applied to the wrong voltage 9 Any labels or cord tags have been removed Replacing Batteries Wear full eye protection and protective clothing When replacing the batteries use the same type and...

Page 8: ...rews are tightened to 75 pound inches 4 Check fuse link for blown fuses The system is stuck in a fault that won t clear 1 Reboot the system a While in AC mode disconnect the positive red wire from the...

Page 9: ...nput Voltage LOST The unit has detected a loss of AC power from the utility and has switched to DC mode The unit must detect good AC voltage before switching back to AC mode 3 AC Input Voltage UNDERVO...

Page 10: ...into a fault condition and has suspended all operations The display shows time left before operations can begin again Normal operation will resume after the timer expires 9 Sumpro Status INVERT SUSPEN...

Page 11: ...t and send back to Metropolitan Ind Warranty Department P O Box 7266 Romeoville IL 60446 Or to register online go to www ionproducts net Sumpro Warranty Registration Card To register your purchase ple...

Page 12: ...ect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until...

Reviews: