23
Ioline
Cleaning the Platen
As the plotter is used, dust and paper residue will accumulate on the platen.
This debris may accumulate as often as every two weeks.
1. Turn off power to the plotter.
2. Dampen a lint-free cloth with isopropyl (pharmacy) alcohol and gently
wipe the platen until any accumulated residue is removed. Use antistatic
spray instead of isopropyl alcohol if desired.
Cleaning the Support Blocks
Dust and paper residue will accumulate on the take-up and feed shaft support
blocks. Perform this procedure when debris inhibits easy rotation of the shafts.
1. Turn off the power to the plotter.
2. Remove the feed shaft and the take-up shaft.
3. Dampen a lint-free cloth with isopropyl (pharmacy) alcohol and gently
wipe the support blocks until any accumulated residue is removed.
4. Wipe down both ends of the feed shaft and the take-up shaft before rein-
stalling them.
4. Precisely measure both sides (X) and the top and bottom (Y) of the box in
either inches or centimeters (dependent on the Measurement Units set-
ting) and record the results. Better accuracy in measurement equals bet-
ter calibration.
5. Take the average of the horizontal (Y) values by adding them together
and dividing by 2. Repeat this procedure for the vertical (X) values.
Example:
If X1 = 39.750 in. and X2 = 39.700 in.
The sum is 79.450 in. (39.750 in. + 39.700 in. = 79.450 in.).
The average is 39.725 in. (79.450 in. / 2 = 39.725 in.)
The X calibration value is the average, 39.725 in.
Enter the Calibration Data:
1. Enter the measured values in the boxes in the Calibration window. Make
sure the plotter is in Start mode (green LED). Select the Set Calibration
button.
2. The plotter will send the calibration values to the plotter and the new
Calibration Setting will be displayed in the boxes in the window.
3. Click on Done when finished.
Figure 17. The Calibration Box and Measurements.
Note: Only use Reset Calibration to restore original factory cali-
bration settings.
Y1
Y2
X1 X2
~40 in.
Figure 18. Do Not Touch the Take-Up Key While it is Moving.
Warning: Never touch the take-up key or flange coupling while
they are rotating (see Figure 18). Serious personal injury could re-
sult.