Goodrive300-01A series VFD for air compressor
Function code description
-55-
Function
code
Name
Description
Default Modify
1: Clear the setting at power-off.
P08.48
High bit of initial value
of power consumption
0
–59999°(k)
0
°
○
P08.49
Low bit of initial value
of power consumption
0.0
–999.9°
0.0
°
○
P08.50 Flux braking coefficient
0: Disable
100
–150: A larger coefficient indicates a
stronger brake intensity.
0
○
P08.51 VFD input power factor 0.00
–1.00
0.56
○
P09 group PID control
Function
code
Name
Description
Default Modify
P09.00 PID reference source
0: Keypad digits (P09.01)
1: Analog P1-
2: Reserved
3: Analog P2-
4: Reserved
5: Multi-step
6: Modbus communication
7
–9: Reserved
10: Pressure setting of dedicated function of
air compressor
0
○
P09.01
PID reference preset
through keypad
-100.0%
–100.0%
0.0%
○
P09.02
PID feedback source
0: Analog P1-
1: Reserved
2: Analog P2-
3: Reserved
4: Modbus communication
5
–7: Reserved
8: Pressure feedback of dedicated function of
air compressor
0
○
P09.03
PID output
characteristics
selection
0: PID output characteristic is positive: the
feedback signal is larger than PID reference,
which requires the VFD output frequency to
decrease to balance PID, e.g. tension PID
control of winding.
1: PID output characteristic is negative:
0
○
Summary of Contents for Goodrive300-01A Series
Page 1: ......
Page 175: ...6 6 0 0 1 0 0 5 5 3...