Goodrive300-01A series VFD for air compressor
Function code description
-47-
P07 group HMI
Function
code
Name
Description
Default Modify
P07.00
User password
0
–65535
0
○
P07.01
Function parameter
copy
0: No operation
1: Uploading function parameters from the
machine to keypad
2: Downloading function parameters
(including the motor parameters) from the
keypad to machine
3: Downloading function parameters
(excluding motor parameters of the P02 and
P12 groups) from the keypad to machine
4: Downloading function parameters (only
motor parameters of the P02 and P12 groups)
from the keypad to machine
Note:
After the parameter is set to 1, 2, 3 or 4, and
the operation is executed, the parameter is
automatically restored to 0.
0
◎
P07.02
Function selection of
the QUICK/JOG key
0: No function
1: Jogging
2: Switching display status through the shifting
key
3: Forward/reverse running switching
4: Clearing the setting of UP/DOWN
5: Coasting to stop
6: Switching running-command giving
methods in sequence
7: Quick debugging mode (non factory
parameter debugging)
1
◎
P07.11
Temperature of rectifier
bridge module
0
–100.0°C
●
P07.12
Temperature of
inverter module
0
–100.0°C
●
P07.13
Software version of
control board
1.00
–655.35
●
P07.14
Accumulated running
time
0
–65535h
●