SYSTEM OVERVIEW: SMOVE CONTROLLER
6
7
sMove controller | Installation instructions
sMove controller | Installation instructions
•
DANGER:
The unit may only be installed by a qualified electrician.
- When laying the power cable, observe the requirements of protection class II.
- Connect all devices of a ventilation system to the same circuit breaker.
- Route and connect cables only while in a voltage-free state!
- The mains supply must correspond to the specifications on the type plate.
- Before working on electrical installations, disconnect all affected units from the power supply.
- Check before making any drill holes whether there are wires in the drilling area.
•
WARNING:
For joint operation of a ventilation device with fireplaces, safety measures must be
taken to prevent a negative pressure from developing in the building. The responsible chimney
sweep and/or building planner decides which measures need to be carried out.
•
NOTICE:
Ensure adequate contact between the wires when connecting the sMove controller.
•
NOTICE:
Laying cables whose sheathing is not resistant to plastering under plaster leads to
short circuits and cable fire! Lay cables without a plaster-resistant cable sheath in the conduit.
•
NOTICE:
The use of too small a cable cross-section leads to too great a voltage drop and/or
contact is not guaranteed!
Use wire ferrules with collars to connect braided wires.
•
NOTICE:
The unit has scratch-sensitive plastic surfaces. Do not touch the components with
oily and/or dirty hands. Avoid contact with sharp or pointed objects, e.g. rings.
• When using several ventilation devices controlled by several controllers, you must ensure that
the ventilation devices are synchronised with each other.
Any kind of use other than the intended use will exclude all liability claims.
Improper use
The sMove controller is intended exclusively for the control of the ventilation devices specified in
the section on intended use. Any other use is strictly prohibited.
Qualified personnel
The equipment/system may only be set up, operated and cleaned in conjunction with this docu-
mentation and the documentation for the controllers.
Installation, electrical connection and commissioning of the equipment/system may only be
performed by qualified personnel. Qualified personnel within the meaning of the safety notices
in this documentation are persons who are authorised to install, put it into operation and identify
equipment, systems and circuits in accordance with established safety procedures.
Conformity
The ventilation device complies with the technical safety requirements and standards of electrical
appliances for domestic use. It conforms to current European Union and United Kingdom
directives. The full text of the EU declaration of conformity is available at the following Internet
address: https://www.inventer.de/downloads/.
2
System overview: sMove controller
The sMove controller is an electronic control unit for controlling inVENTer
®
ventilation devices with
heat recovery. It is available in the variants s4 or s8, each in two versions (standard or flat).
Each sMove controller can control the following maximum number of ventilation devices:
Ventilation units from the product series
Count sMove 4
Count sMove 8
with Xenion fan
4
8
with Xenion EFP/Mini-Xenion fan
2
4
It features a visually discreet, timeless and flat design as well as easy installation. The controller
is operated by touching the capacitive button and the slide control on the control panel. Integrated
indicator lights mean that the control panel acts simultaneously as a visual feedback / display for
the user.
The sMove controller can be used either as a base control unit or with additional sensors
connected.
When used as a base control unit, there is a choice of operating modes for the ventilation device
and the air flow can be set steplessly or at 4 predefined levels.
An external interface allows the scope of functions to be expanded:
• Demand-based ventilation via sensor technology (humidistat, CO2 sensor, VOC sensor
1)
[NO]), or
• Integration of a safety device (e.g. pressure monitor, [NC]) with simultaneous operation of the
ventilation devices with fireplaces.
• Integration of the sMove controller into an existing building management system via an ana-
logue input
Components
• Mounting plate
• Operating unit
• Switching power supply unit
2)
• Mounting box (optional)
Versions
The sMove controller is available in standard and flat versions.
In both versions, the external interface can be configured either as an external switching contact
or as an analogue input.
Flat version:
The controller switches off the ventilation device for 1 hour when in "Off" mode.
The ventilation device then continues to operate using the previously saved operating mode and
ventilation level. The use of the Flat version is recommended in areas where it is desirable not to
turn off the ventilation system in order to protect against moisture build-up.
Standard version:
The sMove controller switches the ventilation device off completely when in
"Off" mode. For the ventilation device to work again, a ventilation level must be selected.
1)
VOC = volatile organic compounds
2)
optionally as a flush-mounted or DIN rail switching power supply unit