The flush-mounted switching power supply unit is 

placed in the lower area of the double-chamber 

mounting box. 

18

19

INSTALLATION

INSTALLATION

18

19

sMove controller | Installation instructions

sMove controller | Installation instructions

 

Place the power supply unit in the lower cavity area 

of the mounting box.

The switching power supply unit output 

wires extend into the interior.

 

The flush-mounted switching PSU is connected.

5.3  Distributing fan cables

We recommend the star-shaped connection of fans to the sMove controller.  

The distribution of wires to the fan in this case takes place within the prepared mounting box using 

5-pole connection terminals. Alternatively, the fans can be connected in sequence. In this case, 

no distribution takes place. The fan BUS is attached directly to the terminal on the operating unit. 

Note the connection capacity of the screw terminal of no more than 1.5 mm

2

.

Stripping tool, crimping tool, fan BUS connecting cable, 3-wire, terminal blocks (5-pole 

(3x), included scope of supply)

Requirements:

•  The switching power supply unit is attached.

 

Connect the fan BUS cables to a terminal block, 

5-pole, as follows:

The wire ends

•  of the same colour

•  ventilation devices operated in pairs

attach together with one pole of a terminal block

 

A maximum of 4 poles are occupied with 1 wire 

each.

 

Attach the wire ends of the additional connecting 

cable, 3-wire, to the terminal block of the corre-

sponding colour (1).

 

Place the connected terminal blocks in the mount-

ing box (2).

 

The connecting cable extends out of the mounting 

box.

5.2  Connecting the switching power supply unit

Flush-mounted switching power supply unit: Terminal blocks, 2-pole

Requirements:

•  The cables are routed to the installation site.

•  The mounting box is attached.

Control cabinet switching power supply unit

 

Secure the switching power supply unit to the con-

trol cabinet's DIN rail.

sMove s4: It requires 1.5 HP of space. 

sMove s8: It requires 4.5 HP of space.

 

Connect the switching power supply unit:

•  Attach the phase conductor to terminal L

•  Attach the neutral conductor to terminal N

•  Attach the (red) wire to the (+) terminal.

•  Attach the (blue) wire to the (–) terminal.

 

The control cabinet switching power supply unit is 

connected.

Flush-mounted switching power supply unit

 

Connect the 

power supply unit input wires

 (blue/

brown) using the terminal blocks:

•  Connect the phase conductor (brown) to wire L.

•  Connect the neutral conductor (blue) to wire N.

 

The fan cables are distributed.

24 V DC 

230 V AC  

1

2

3

4

L

N

+

230 V AC  

24 V DC 

2

1

!

Summary of Contents for 3002-0396

Page 1: ...www inventer de Installation instructions sMove Control unit...

Page 2: ...imer This documentation represents a translation of the original German installation instructions Information on how to access the installation instructions must be provided to the user tenant owner p...

Page 3: ...ons that precede the described handling instructions Non obser vance of safety instructions could result in injury and or property damage Intended use The sMove control unit also referred to in the fu...

Page 4: ...rocedures Conformity The ventilation device complies with the technical safety requirements and standards of electrical appliances for domestic use It conforms to current European Union and United Kin...

Page 5: ...ilation system into an existing building management system A Interface configured as external switching contact sensor system If sensors are connected to the sMove controller the range of the controll...

Page 6: ...pply unit AC L Phase Brown AC N Neutral conductor Blue Controller operating voltage Output cable for switching power supply unit 24 V Controller operating voltage Red GND Black Rear view of sMove cont...

Page 7: ...ing power supply unit Maximum cable lengths Cable Cross section cable type and cabling Maximum length controller last connected unit Operating voltage 2x 1 0 mm 24 V DC between switching power supply...

Page 8: ...y only be changed in a de energised state Function assignment depending on the switching contact NO closer NC opener Sensor Position of jumper 2 Function with switch actuation switching attached Norma...

Page 9: ...trical components Electric shock and injury due to live components 230V 50Hz Installation and connection must only be performed by qualified and trained personnel 5 1 Routing wires and attaching the m...

Page 10: ...The wire ends of the same colour ventilation devices operated in pairs attach together with one pole of a terminal block A maximum of 4 poles are occupied with 1 wire each Attach the wire ends of the...

Page 11: ...ting unit 3 The base plate has been removed from the operating unit Screw the operating unit base plate to the box using fixing screws The arrow above the lettering TOP is pointing upwards NOTICE If t...

Page 12: ...of the receptacle for the control unit lock and the lever on the base plate match Slide the operating unit downwards as far as the stop The operating unit should snap audibly into place 6 Technical da...

Page 13: ...flush mounted power supply unit 1003 0149 Flush mounted box 60x90 incl compensating ring s4 with flush mounted power supply unit 1003 0104 Round cable LiYY O 3x0 75 33m 1004 0020 9 Troubleshooting Fau...

Page 14: ...oduct wear Guarantee and warranty claims Further information about the guarantee is available at www inventer de garantie In the case of a guarantee or warranty claim contact your local distributor or...

Page 15: ...Item number 5021 0029 Version 1 0 10 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstra e 4a 07751 L bersch tz Germany www inventer eu...

Reviews: