5.4  Installing the operating unit

The control unit is mounted on the prepared controller mounting box. The fan cables are in the 

box and are already distributed in it. Depending on the installation scenario, the switching power 

supply is located in the control cabinet or in the lower area of the mounting box.

To connect an optional sensor, e.g. CO

2

 sensor or to a home automation system, follow the 

instructions in grey italics.

Stripping tool; crimping pliers; screwdriver

Requirements:

•  The switching power supply unit is attached.

•  The fan wires are distributed.

 

Pull the lever on the lower right side of the operat-

ing unit backwards (1).

 

Slide the base plate downwards as far as the stop 

(2).

 

The operating unit is unlocked.

 

Remove the base plate from the operating  

unit (3).

 

The base plate has been removed from the 

operating unit.

 

Screw the operating unit base plate to the box 

using fixing screws.

The arrow above the lettering TOP is 

pointing upwards.

!

NOTICE: If 

the terminals are connected 

incorrectly, the sMove controller or connected 

components will not work!

•  Ensure the correct terminal assignment 

when connecting the cables.

 

Attach the cables to the back of the operating unit:

•  Operating voltage cable

, 2-core, in the two 

upper poles of the 5-pole connection terminal: 

- Red wire (+) to the first connecting pole

 

- Black wire (

) to the second connecting pole;

•  Fan BUS

, 3-wire, in the three lower poles of the 

connection terminal; 

- DIR1 (III) in the third connection pole 

- VOUT+

(IV

) in the fourth connection pole 

- DIR2 (V) in the fifth (lower) connection pole;

•  Optional:

 Sensor cable

, 2-wire, to the 2-pole 

connection terminal.

Termi

-

nal

Meaning

Colour

+ 24 V

Supply voltage

24 V DC

Red

GND

Black

DIR1

Direction signal 1

White

VOUT+ Fan operating voltage

Green

DIR2

Direction signal 2

Brown

SC1 (+) External interface 

(optional sensor)

SC2 (–)

1

2

3

1

2

3

+ 24 V

DIR1

VOUT+

DIR2

SC1

SC2

Summary of Contents for 3002-0396

Page 1: ...www inventer de Installation instructions sMove Control unit...

Page 2: ...imer This documentation represents a translation of the original German installation instructions Information on how to access the installation instructions must be provided to the user tenant owner p...

Page 3: ...ons that precede the described handling instructions Non obser vance of safety instructions could result in injury and or property damage Intended use The sMove control unit also referred to in the fu...

Page 4: ...rocedures Conformity The ventilation device complies with the technical safety requirements and standards of electrical appliances for domestic use It conforms to current European Union and United Kin...

Page 5: ...ilation system into an existing building management system A Interface configured as external switching contact sensor system If sensors are connected to the sMove controller the range of the controll...

Page 6: ...pply unit AC L Phase Brown AC N Neutral conductor Blue Controller operating voltage Output cable for switching power supply unit 24 V Controller operating voltage Red GND Black Rear view of sMove cont...

Page 7: ...ing power supply unit Maximum cable lengths Cable Cross section cable type and cabling Maximum length controller last connected unit Operating voltage 2x 1 0 mm 24 V DC between switching power supply...

Page 8: ...y only be changed in a de energised state Function assignment depending on the switching contact NO closer NC opener Sensor Position of jumper 2 Function with switch actuation switching attached Norma...

Page 9: ...trical components Electric shock and injury due to live components 230V 50Hz Installation and connection must only be performed by qualified and trained personnel 5 1 Routing wires and attaching the m...

Page 10: ...The wire ends of the same colour ventilation devices operated in pairs attach together with one pole of a terminal block A maximum of 4 poles are occupied with 1 wire each Attach the wire ends of the...

Page 11: ...ting unit 3 The base plate has been removed from the operating unit Screw the operating unit base plate to the box using fixing screws The arrow above the lettering TOP is pointing upwards NOTICE If t...

Page 12: ...of the receptacle for the control unit lock and the lever on the base plate match Slide the operating unit downwards as far as the stop The operating unit should snap audibly into place 6 Technical da...

Page 13: ...flush mounted power supply unit 1003 0149 Flush mounted box 60x90 incl compensating ring s4 with flush mounted power supply unit 1003 0104 Round cable LiYY O 3x0 75 33m 1004 0020 9 Troubleshooting Fau...

Page 14: ...oduct wear Guarantee and warranty claims Further information about the guarantee is available at www inventer de garantie In the case of a guarantee or warranty claim contact your local distributor or...

Page 15: ...Item number 5021 0029 Version 1 0 10 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstra e 4a 07751 L bersch tz Germany www inventer eu...

Reviews: