10
Selecting a Battery Charger
Many types of lead acid chargers are compatible with our PROTRXion™ batteries and safely
charge in temperature ranges as shown in the table below. The charger maximum voltage output
should match the maximum charge voltage of the battery system and should not exceed charge
voltage as shown in the table below. It is recommended to charge the battery prior to installation.
Consult with Inventus Power for recommendation on selecting a battery charger.
After the charger has been selected, first connect the (-) terminal to the battery, then the (+)
terminal. Once the terminals have been connected, connect the CAN communication to the
battery to optimize the charger performance (preferred chargers recommended by Inventus
Power).
Charge Voltage / Current
Float Charge Voltage
Charger Current
Max charge current rate will vary depending on ambient temperature and battery state of charge.
Charging above the recommended current rate may impact the battery cycle life. For more de-
tailed information on charging profile, please discuss with Inventus Techincal Support.
When choosing an intelligent charger, please discuss with Inventus Technical Support on suitable
off-the-shelf charger solutions.
Model
M-24V60-TRX
Max Charge Voltage
28.0 VDC
Charge Current
30A (0.5C)
Max Charge Current
60A (1.0C)
Charge Temperature
(without heater)
0°C to 55°C
(32°F to 131°F)
Model
M-24V60-TRX
Float Voltage
27.6 VDC