![INVENTOR V5MFI-66 User & Installation Manual Download Page 28](http://html1.mh-extra.com/html/inventor/v5mfi-66/v5mfi-66_user-and-installation-manual_2084168028.webp)
Page 28
B
A
D
The mounting dimensions vary among
different outdoor units.
The fixing bolt head diameter should be
more than 12mm.
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
952
1333
415
634
404
900
1170
350
590
378
W
H
Step 2: Install drain joint
(Heat pump unit only)
Before bolting the outdoor unit in place, you must
install the drain joint at the bottom of the unit.
Note that there are two different types of drain
joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal
(see
Fig. A
), do the following:
1.
Fit the rubber seal on the end of the drain joint
that will connect to the outdoor unit.
2.
Insert the drain joint into the hole in the base
pan of the unit.
3.
Rotate the drain joint 90° until it clicks in place
facing the front of the unit.
4.
Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
If the drain joint doesn’t come with a rubber
seal
(see
Fig. B
), do the following:
1.
Insert the drain joint into the hole in the base
pan of the unit. The drain joint will click in
place.
2.
Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
Seal
Drain joint
(A)
(B)
Base pan hole of
outdoor unit
Seal
IN COLD CLIMATES
In cold climates, make sure that the drain
hose is as vertical as possible to ensure
swift water drainage. If water drains too
slowly, it can freeze in the hose and flood
the unit.
Step 3: Anchor outdoor unit
Page 29
Rows of series installation
L
≤
H
L
≤
1/2H
L
A
25 cm / 9.8” or more
1/2H < L
≤
H
30 cm / 11.8” or more
L
>
H
Can not be installed
The relations between H, A and L are as follows
W
H
A
B
D
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
681
434
285
460
292
700
550
275
450
260
300
333
363
420
555
554
702
810
770
800
845
946
487
514
540
673
298
340
350
403
417
1333
958
634
404
328
555
807
514
340
L
H
300 cm / 118” or more
A
60 cm / 23.6”
or more
150 cm / 59”
or more
25 cm / 9.8”
or more
25 cm / 9.8”
or more
Summary of Contents for V5MFI-66
Page 41: ...43 47 1 47 2 47 3 48 49 54 56...
Page 43: ...43 server 8...
Page 44: ...44 3mm...
Page 46: ...46 R32 R290 R32 X m X m 3g 25 UL IEC ISO 14903 Btu h kg m m 48000 3 0 0 6 m 80...
Page 49: ...49 1 2 3 4 5 ON OFF MODE FAN FUNC...
Page 51: ...51 Fan speed Fan speed display LOW 1 MED 2 HIGH 3 AUTO HIGH MED LOW LOW MED HIGH AUTO...
Page 53: ...53 LOCK 5 FUN oder FUN...
Page 54: ...54 40 C 104 F 2...
Page 55: ...55 EC FAN...
Page 56: ...56 ON OFF 3 3 FAN FAN...
Page 57: ...57...
Page 58: ...58 3 3 10 E x P x F x EH xx EL xx EC xx PH xx PL xx PC xx...
Page 60: ...60 MC MC L N 1 2 3 4 5 6...
Page 61: ...61 1 7 8 9 10 2 3 4 5 6 1 2 3 4 5 6 7 10 9 8...
Page 62: ...62 1 o o o o o o 1 c x x x x 5cm 2in 200cm 78 7 in 30cm 11 8in 50cm 19 7 in 50cm 19 7 in...
Page 63: ...63 3 2 1 2 3 4 3 1 2 4 1 2 M8 3 5 1 2 3 6 1 2...
Page 64: ...64 7 1 2 3 8 1 2 65mm 1cm 0 4 67 57 4 67 4...
Page 65: ...65 1 2 PVC 26mm 3 0 03 9mm 4 5 6 3 9 5cm S U 0 5 1cm 0 2 0 4 inch 3 7 3 9cm 3 2cm...
Page 72: ...72 1 2 3 4 90 100 5 1 5 6 1 8in 3mm 7 8 9 10 1 40in 11 12 10 13 14 32ohms 15 16...
Page 74: ...74 b 15cm 6in c d 2 3 4 5 6 2 1 a 15cm 6in b c 2 3 4 5 Abgedeckt Impressum...
Page 75: ...75 76cmHg o o 1 2 3 4 5 15 76cmHG 105Pa 6 7 5 8 9 1 4 5 10 11 12 13 76cmHg...
Page 77: ...77 a b c d e f g h i 1 2 3 4 a b c d e f g 5 a b c 6 a b 2 000ml c d e f g...
Page 78: ...211 300 3300 www inventoraircondition gr media library...
Page 158: ...NOTES...
Page 159: ......