![INVENTOR ICI-12 Owner'S Manual Download Page 57](http://html1.mh-extra.com/html/inventor/ici-12/ici-12_owners-manual_2084043057.webp)
(
3
)
Connect the power supply cable to the “L, N”
terminals and
Caution:
Take great care when carrying out the
following connections, so as to avoid
malfunction of the air-conditioning unit
because of electromagnetic interference.
(1) The signal line of the wire controller must
be separated from the power line and the
connecting line between the indoor unit and
the outdoor unit.
(2) In case the unit is installed in a place
vulnerable by electromagnetic interference, it
is better to use shielded cable or
double-twisted cable as the signal line of the
wire controller.
the grounding screw.
(
4
)
Use cable fastener to bundle and fix the cable.
2. Air-conditioning unit with 3-phase power supply
(
1
)
Remove the front-side panel of the outdoor unit.
(
2
)
Attach rubber ring to the cable-cross hole of the
outdoor unit.
(
3
)
Pass the cable though rubber ring.
(
4
)
Connect the power cable to the terminal and
earthing screws marked “L1, L2, L3 & N”.
(
5
)
Use cable fastener to bundle and fix the cable.
10.5 Products Electric Installation
Wiring layout
☆
Installation should be conducted by National Wiring Regulation.
☆
The rated voltage and exclusive power supply must be adopted for the air conditioners.
☆
The power cable should be reliable and fixed, in order to avoid the wiring terminal be suffered
from force. And do not drag the power cable forcibly.
☆
The wire diameter of power cable should be large enough, if power cable and connection wire
be damaged, it should be replaced by the exclusive cable.
☆
All electric installation must be done by professional personnel according to local law,
regulation and this manual.
☆
It should be reliably earthed, and it should be connected to the special earth device, the installation
work should be operated by the professional.
☆
The creepage protect switch and air switch must be installed.
Air switch should have the thermal dropout and magnetic dropout function, in order to avoid the
55
Summary of Contents for ICI-12
Page 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Page 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Page 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Page 22: ...TIMER operation procedure 20...
Page 24: ...How to inser t batteries 22...
Page 35: ...6 Optimum operation 33...
Page 37: ...The following are not troubles 35...
Page 38: ...8 Installation notes This should be done by professional 36...
Page 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...