Caution:
(
1
)
Do not wrap the protective tape too tight, otherwise the efficiency of thermal insulation
may be decreased. Ensure that the condensate drainage flexible tube is separate from the
bundled pipes.
(
2
)
After the protective work is completed and the pipes are wrapped, use seal material to
block the hole in the wall, so as to prevent rain and wind from entering the room.
G
、
Position and Method of Installing Wire Controller
1
、
First select an installation position. According to the size of the communication line of the
wire controller, leave a recess or a embedded wire hole to bury the communication line.
2
、
If the communication line between the wire controller (85
×
85
×
16) and the indoor unit is
surface-mounted, use 1# PVC pipe and make matching recess in the wall (refer to Figure 6);
If concealed installation is adopted, 1# PVC pipe can be used (Refer to Figure 7).
3
、
No matter if surface mounting or concealed mounting is selected, it is required to drill 2
holes (in the same level) which distance shall be the same as the distance (60mm) of
installation holes in the bottom plate of the wire controller. Then insert a wood plug into
each hole. Fix the bottom plate of the wire controller to the wall by using the two holes.
Plug the communication line onto the control panel. Lastly install the panel of the wire
controller.
Caution:
1.During the installation of the bottom plate of the wire controller, pay attention to the
direction of the bottom plate. The plate’s side with two notches must be at the lower position, and
otherwise the panel of the wire controller cannot be correctly installed.
2
3
4
1
PVC管
Fig 6 Surface Mounting of Cable
Fig 7 Concealed mounting of Cable Fig 8 Schematic Diagram of Installation
PVC Pipe
52
Summary of Contents for ICI-12
Page 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Page 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Page 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Page 22: ...TIMER operation procedure 20...
Page 24: ...How to inser t batteries 22...
Page 35: ...6 Optimum operation 33...
Page 37: ...The following are not troubles 35...
Page 38: ...8 Installation notes This should be done by professional 36...
Page 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...
Page 63: ......