Please refer to the install cardboard about the dimension of ceiling opening.
☆
The central mark of the ceiling opening is marked on the install cardboard.
☆
Install the install cardboard on the unit by bolt (3 piece), and fix the angle of the drainage pipe at
the outlet vent by bolt.
3
、
Adjust the unit to the suitable install place.
4
、
Check if the unit is horizontal.
☆
Inner drainage pump and bobber switch are included in the indoor unit, check if 4 angle of every
unit are horizontal by water lever. (If the unit is slant toward the opposite of the coagulate water
flow, there may be malfunction of the bobber switch and lead water drop.)
5
、
Backout the gasket anchor board used to prevent gasket break off and tighten the nut on it.
6
、
Backout the install cardboard.
Note
!
●
Please do tighten the nuts and bolts to prevent air conditioner break off
.
F
、
Connect the refrigerant pipe
☆
Selection of Connecting Pipe
Size of Fitting Pipe
( I n c h )
Item
Model
Gas Pipe Liquid Pipe
Max. Pipe
Length (m)
Max. Height
Difference
b e t w e e n
Indoor Unit
and Outdoor
U n i t ( m )
Amount of Additional
Refrigerant to Be
Filled(For Extra
Length of Pipe)
1/2
1/4
20
15
30g/m
5/8
3/8
30
15
60g/m
3/4
1/2
50
30
120g/m
41
ULS 12
ULS 18
ULS 24
ULS 36
ULT 36
ULT 45
ULT 50
Summary of Contents for ICI-12
Page 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Page 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Page 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Page 22: ...TIMER operation procedure 20...
Page 24: ...How to inser t batteries 22...
Page 35: ...6 Optimum operation 33...
Page 37: ...The following are not troubles 35...
Page 38: ...8 Installation notes This should be done by professional 36...
Page 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...
Page 63: ......