32
Fig.19
memorize startup and stop status of the unit or not at unit.01
displayed in the region of displaying setting temp indicates
memorizing start and stop status of the unit after power
off .02, quit by pressing ON/OFF button ,indicates not
memorizing. If after the interface of memorizing startup and
stop status of the unit appears, there is no operation in 20s
when the system responds the last press of one button, the
system will trip off the menu and display normal stop interface,
but it also memorizes present information.
10
)
Malfunction Display (Fig.19)
If malfunction happens during operating of the unit, ERROR will
blink with error code displayed. For example, the right figure
indicates compressor low-pressure protection.
Codes Malfunction
E0 Water
pump
malfunction
E1 Compressor
high-pressure
protection
E2
Indoor anti-freezing protection
E3 Compressor
low-pressure
protection
E4
Compressor high-temp. exhaust protection
E5 Compressor
overload
protection
E6 Communication
malfunction
E8
Indoor fan protection
E9 Water-full
protection
F0
Air inlet indoor ambient temp. sensor malfunction
F1
Evaporator temp. sensor malfunction
F2
Condenser temp. sensor malfunction
F3
Outdoor ambient temp. sensor malfunction
F4
Exhaust ambient temp. sensor malfunction
F5
Ambient temp. sensor malfunction in displayer
EH
Auxiliary electric heat malfunction
Note!
If EH malfunction happens, please power the unit off immediately and ask professionals for
help
。
Fig.19
Fig.18
Summary of Contents for ICI-12
Page 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Page 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Page 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Page 22: ...TIMER operation procedure 20...
Page 24: ...How to inser t batteries 22...
Page 35: ...6 Optimum operation 33...
Page 37: ...The following are not troubles 35...
Page 38: ...8 Installation notes This should be done by professional 36...
Page 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...
Page 63: ......