38
SPECIFICATIONS
inVENTer PAX standard set
•
Installation and operating instructions
7
Specifications
Main module
Feature
Value
Outside temperature [°C]
-30 – 35
Indoor temperature [°C]
5 – 35
Extract air/Outdoor air
Free from aggressive gases, dust and oils
Type of protection
IP24
Protection class
II
Input voltage [V AC/Hz]
230/50
Standard sound level differential [dB]
(exhaust air area)
47
Standard sound level differential [dB]
(supply air area)
77
Output level
Low
Moderate
High
only ex-
haust air
Airflow (free blowing) [m³/h]
30
52
78
90
Noise emissien (rated) [dB (A)]
19
22
29
35
Power consumption [W]
3.5
8.0
18.0
25.0
Max. Power consumption with heating [W]
< 375
< 375
375
–
Heat recovery [η'
w
]
0.8
0.78
0.75
–
Leakage loss [%]
5
Energy efficiency class
A
Wall thickness with render [mm]
100 – 600
Wall opening [mm]
2 x Ø 160
Dimensions [W x H x D in mm]
720 x 340 x 191
Weight [g]
9500
Wall duct (Insulating sleeve with folded spiral-seam duct)
Feature
Value
Length/Diameter (single) [mm]
600/140
Weight [g]
2500