30
INSTALLATION AND ASSEMBLY
30
iV-Smart+ ventilation unit | Installation instructions
1.1 Inserting the thermal accumulator insert
NOTICE
Do not store/stack the thermal accumulator insert outside the wall sleeve
as doing so will damage the thermal accumulator's ceramic.
• Insert the thermal accumulator immediately after removing it from the packaging.
Requirements:
•
The external termination is fitted.
►
Remove the Styrofoam disc from the wall sleeve.
►
Insert the thermal accumulator from the interior into
the wall sleeve.
•
The handle points towards the interior.
•
The connecting cables protrude into the
interior.
►
From the interior, slide the thermal accumulator
towards the external termination as far as the
end-stop tape.
►
Insert the inVENTron from the interior into the
wall sleeve so that you can reach the BUS plug
connection.
Make sure that the narrow Slim guiding
vane [16 mm] is directed towards the
interior.
The thermal accumulator insert has been inserted.
Slim
Standard
!
!