Hardware Operations
2017-MNU-000016
2-22
2.11
2.5” HDDs
The server can support 8x2.5” hot-pluggable HDDs. Each HDD is with an adapter bracket.
You don’t need to power-off the system when removing or installing a HDD.
The location of the 2.5” HDDs on the server is shown below:
Figure 2-23 2.5” HDD Locations
2.11.1
To remove the 2.5” HDD
Push the release button.
Pull the lever open.
Slide the HDD assembly out of the HDD bay.
Figure 2-24 Sliding out the 2.5” HDD Assembly
•
Take note of the drive tray orientation before sliding it out.
•
The tray will not fit back into the bay if inserted incorrectly.