K800G4 BMC Specification
23
Table B3 , Compact Sensor Record
15
16
17
18
19
20
21
Sensor Number
0xB8
0xB9
0xBA
0xBB
Sensor Name
CPU1_PROCHOT
CPU2_PROCHOT
CPU3_PROCHOT
CPU4_PROCHOT
Sensor Type
0x01
0x01
0x01
0x01
Event Type
0x03
0x03
0x03
0x03
Entity ID
0x03
0x03
0x03
0x03
Instance
0x00
0x00
0x00
0x00
Initialization
0x67
0x67
0x67
0x67
Capabilities
0x40
0x40
0x40
0x40
AE/LTR Mask
0x0002
0x0002
0x0002
0x0002
AE/LTR (BIT)
1/
1/
1/
1/
DE/UTR Mask
0x0002
0x0002
0x0002
0x0002
DE/UTR (BIT)
1/
1/
1/
1/
DR/ST/RT Mask
0x0002
0x0002
0x0002
0x0002
DR/ST/RT (BIT)
1/
1/
1/
1/
SRS/SD
0x0100
0x0100
0x0100
0x0100
SRS/SD (BIT)
8/
8/
8/
8/
Table C1 , Event Only Sensor Record
1
2
3
4
5
6
7
Sensor Number
0xF4
0xF9
0xFC
0xF5
Sensor Name
START_OF_POST
MngSysHealth
BUTTON
NMI
Sensor Type
0x12
0x28
0x14
0x13
Event Type
0x6F
0x6F
0x6F
0x6F
Entity ID
0x22
0x2E
0x0C
0x2E
Instance
0x00
0x00
0x00
0x00
SRS/SD
0x0000
0x8101
0x0000
0x0000
SRS/SD (BIT)
0/8/15/
AM/LTR : Assertion Event Mask / Lower Threshold Reading Mask
DEM/UTR : De-assertion Event Mask / Upper Threshold Reading Mask
DE/UTR: Discrete Reading Mask / Settable Threshold Mask, Readable Threshold Mask
LNR : Lower non-recoverable Threshold
LC : Lower critical Threshold
LNC : Lower non-critical Threshold
UNC : Upper non-critical Threshold
UC : Upper critical Threshold
UNR : Upper non-recoverable Threshold
11.2
Automatic CPU Thresholds (for Intel Platform only)
Items
Rule
CPU Maximum Temperature
CPU T-JMAX
(It is according to CPU Specification)
Upper Non-Recoverable Temperature
CPU T-JMAX
Upper Critical Temperature
CPU T-JMAX - 1
Upper Non-Critical Temperature
CPU T-JMAX - 2
CPU Thresholds of SDR (static) are default values. (please
ignore
CPU thresholds of SDR)
The values are changed on Sensor(dynamic) rather than SDR(static) after system power on.
Summary of Contents for P47 series
Page 1: ...P N 2017 MNU 000016 June 2018 Revision A 2U Server System Service Manual P47 ...
Page 3: ......
Page 64: ...Backplane Connectors OCP Card Connectors Chapter 3 Connectors ...
Page 67: ...Chapter 4 Cable Routing ...
Page 68: ...Cable Routing 2017 MNU 000016 4 1 4 Cable Routing ...
Page 69: ...China RoHS Regulations Taiwan BSMI Electromagnetic Emissions Notices Appendix 1 ...
Page 71: ...Appendix 2017 MNU 000010 II Taiwan BSMI Figure II Taiwan BSMI ...
Page 75: ...Appendix 2 BIOS SPEC ...
Page 76: ...BIOS Setup User Manual K800QG4 rev 0 01 Mar 2018 ...
Page 100: ...Appendix 3 BMC SPEC ...
Page 101: ...K800G4 BMC Specification 1 K800G4 BMC Specification June 22th 2018 ...