![Invacare Action Vertic User Manual Download Page 47](http://html1.mh-extra.com/html/invacare/action-vertic/action-vertic_user-manual_2082399047.webp)
9.2 Identifying and repairing faults
Fault
Possible cause
Action
Incorrect tire pressure on one rear wheel
Correct tire pressure, →
The wheelchair does not
travel in a straight line
One or more spokes broken
Replace faulty spoke(s), → authorized dealer
Spokes tightened unevenly
Tighten loose spokes, → authorized dealer
Front wheel bearings are dirty or damaged
Clean or replace the bearings, → authorized
dealer
Incorrect tire pressure in one or both rear
tires
Correct tire pressure, →
The brakes are gripping
poorly or asymmetrically
Brake setting incorrect
Correct the brake setting, → authorized dealer
Tire pressure in rear tires is too low
Correct tire pressure, →
Rolling resistance is very
high
Rear wheels not parallel
Ensure the rear wheels are parallel, → authorized
dealer
Too little tension in front wheel bearing block
Tighten the nut on the bearing block axle slightly,
→ authorized dealer
The front wheels wobble
when moving fast
Front wheel has worn smooth
Change front wheel, → authorized dealer
The front wheel is stiff or
stuck
Bearings are dirty or faulty
Clean or replace the bearings, → authorized
dealer
1648806-B.00