Open-Q™ 624A Development Kit
Open-Q™ 624A Development Kit User Kit
27
Table 3-8. Power Header J26 Pin-out
Signal
Description
Pin # Signal
Description
Pin #
GND
GND
J26[1] GND
GND
J26[2]
BATT_P
Battery plus (+) terminal sense
J26[3] PMI_VDD_CAP
LDO to supply fuel gauge
circuits. Connect to bypass
capacitor only, Do Not
Load.
J26[4]
BATT_N
Battery minus (-) terminal sense
J26[5] CHG_VBAT_SNS
Sensed battery voltage for
charger circuits
J26[6]
BAT_ID
Battery ID, MIPI Battery interface,
detects missing battery
J26[7] PMI_CHG_EN
Charger Enable
J26[8]
BAT_THERM
Battery temperature input used
by FG and by charger to ensure
safe operation
J26[9] SMB_PARALLEL_CHG_EN SMB1350/SMB1351
enable for parallel charging J26[10]
PM_VREG_BATT_THERM
Not Connected on Open-Q 624A
SOM
J26[11] SMB_INT
Leave Floating
J26[12]
GND
GND
J26[13] SMB_STAT_N
Not Connected on Open-Q
624A SOM
J26[14]
PMI_GPIO_1
Software Configurable GPIO,
WiPower long beacon extension
(LBE) control
J26[15] FG_ALARM
Not Connected on Open-Q
624A SOM
J26[16]
NC
NC
J26[17] BATT_CHG_EXP_TP2
Testpoint 2
J26[18]
BATT_CHG_EXP_TP1
Testpoint 1
J26[19] GND
GND
J26[20]
GPIO_5_BLSPx_UART_RX UART RX
J26[21] OPT_1
Leave Floating
J26[22]
GPIO_4_BLSPx_UART_TX UART TX
J26[23] OPT_2
Leave Floating
J26[24]
GPIO_7_BLSPx_I2C_SCL
I2C Clock
J26[25] BATT_EXP_1P8
1.8V voltage supply
J26[26]
GPIO_6_BLSPx_I2C_SDA
I2C Data
J26[27] GND
GND
J26[28]
GND
GND
J26[29] BATT_EXP_SYS_PWR
Battery Voltage Supply
J26[30]
GND
GND
J26[31] BATT_EXP_SYS_PWR
Battery Voltage Supply
J26[32]
GND
GND
J26[33] BATT_EXP_SYS_PWR
Battery Voltage Supply
J26[34]
BATT_EXP_USB_VBUS
USB VBUS
J26[35] GND
GND
J26[36]
BATT_EXP_USB_VBUS
USB VBUS
J26[37] GND
GND
J26[38]
BATT_EXP_USB_VBUS
USB VBUS
J26[39] GND
GND
J26[40]