Continued
Procedure for WiBAS-Connect TS with Parabolic Integrated Antenna
, continued
Step
Action
3
Perform fine alignment,
as follows:
•
Use the spanner key to loosen the azimuth adjustment bolts
(A1).
Perform azimuth
adjustment by rotating the bolts
(A2)
of the antenna mounting kit until the voltage readout
reaches a desired level.
•
Use the spanner key to loosen the elevation adjustment bolts
(E1).
Perform elevation
adjustment by rotating the bolt
(E2)
of the antenna mounting kit until the voltage readout
reaches a desired level.
The RSSI voltage
(actually the voltmeter value)
provides a direct relationship with
RSL.
For
Wibas-OSDR
see
WiBAS-OSDR terminal station RSSI measurement calculation
on page
For
WiBAS-Connect
see
WiBAS-Connect terminal station RSSI measurement
on page
Pre-tightened.
The final tightening torque will be applied after alignment process completion.