Mechanical installation
INTORQ | BA 14.0200 | 02/2016
23
Single-rotor design
Mounting the flange
Fig. 6
Assembly of the flange
1. Check fit of the two O-rings (26) in the flange (6).
2. Position the flange (6) on the end shield.
-
Observe flange position relating to the recesses for the manual release!
-
The chamfer at the flange must be directed towards the motor end shield!
-
Align through holes of the flange (6) with the fixing holes in the end shield (15) and tighten to the
flange using the fixing screws (21). Tightening torque
15 - use a torque wrench!
Assembly of the rotor
Fig. 7
Mounting the single-rotor version
3. Push the rotor (3) onto the hub (4) and check whether it can be moved by hand.
4
Hub 15 End
shield
26 O-rings
6
Flange 21 Fixing
screws
3
Rotor
6
Flange
15 End shield
4
Hub