![Intimus INT-GU-05280EPSHP Operation Manual Download Page 54](http://html1.mh-extra.com/html/intimus/int-gu-05280epshp/int-gu-05280epshp_operation-manual_2081565054.webp)
Operation Manual 5280 EPSHP
54
8.3.3 Use a 3-mm hexagonal key with 3 mm to firmly screw in the screws 3 (Fig. 39) in the
threaded holes in the clamping beam, causing the insert to be blocked in the clamping beam.
8.3.4 Release the pressure on the pedal 2 (Fig. 39) - the beam with the inserted cylinder
returns to the upper position
The removable insert must be attached under the front table!
(Fig. 38)
INFO
The lack of the insert in the place of attachment is treated by the programmer as if it
was mounted in the clamping beam and narrow cut (waste) is greater. Mounting the
insert into the pressure bar causes;
the minimum narrow cut (waste) is 40mm (without insert 22mm),
maximum stack height is 76mm (without 80mm insert)
Figure 39 Operating elements used when mounting the insert into the pressure bar