inti TECA LITIO IIP-241000BFL Manual Download Page 18

18

www.intipv.com

MANUAL DE USUARIO INVERSOR TECA LITIO / USER MANUAL INVERSOR TECA LITIO

SIDE VIEW IIP

-24500BFL, IIP

-241000BFL, IIP-242000BFL

SIDE VIEW IIP-243000BFL

SIDE VIEW 

IIP-484000BFL, IIP-485000BFL

1.On/off

2.Battery negative

3.Battery positive

4.Input / Output

1.RS232 port

2.LCD remote control

3.LED remote control

4.Dry contact

5.On/off

6.Battery negative

7.Battery positive

8.Output inverter protection

9.Load input protection

10.Input / Output

For a proper ventilation, an adequate space in the 

installation and cabling is required for it to improve the air 

flow in the system. The minimum installation distances 

required for the Teca Litio inverter are as follows:

The operation and display panel, shown in the figure 

below, is located on the frontal layout of the inverter and it 

includes 3 indicators, 4 function keys and an LCD screen 

that indicates the operating status and the input/output 

power information. 

INSTALLATION

OPERATION AND DISPLAY PANEL

Summary of Contents for TECA LITIO IIP-241000BFL

Page 1: ...USUARIO INVERSOR TECA LITIO USER MANUAL INVERSOR TECA LITIO Inversor cargador de onda pura de baja frecuencia SERIE TECA LITIO IIP 24500BFL IIP 241000BFL IIP 242000BFL IIP 243000BFL IIP 484000BFL IIP...

Page 2: ...2 www intipv com MANUAL DE USUARIO INVERSOR TECA LITIO USER MANUAL INVERSOR TECA LITIO...

Page 3: ...general del equipo Vistas laterales del equipo Instalaci n Panel de operaci n y visualizaci n pantalla conos y funciones C digos de fallas Especificaciones t cnicas About this manual Safety instructio...

Page 4: ...siga las especificaciones requeridas para seleccionar apropiadamente el tama o del cable Sea cuidadoso trabajando con herramientas de metal alrededor de las bater as Existe el riesgo potencial de deja...

Page 5: ...aplicaciones dom sticas modos de carga de bater a configurables reinicio autom tico por sobre temperatura y protecciones de sobre carga de sobre temperatura y de cortocircuito En caso de que la carga...

Page 6: ...nversor e incluye 3 indicadores 4 teclas de funci n y una pantalla LCD indicando el estado de operaci n y la informaci n de entrada salida de energ a Para una ventilaci n apropiada se requiere un espa...

Page 7: ...rior DOWN Para ir a la siguiente selecci n ENTER Para confirmar la selecci n en el modo de configuraci n cono Descripci n de funci n Informaci n de fuente de entrada Indica la entrada AC Indica voltaj...

Page 8: ...tar encendida y la primera barra encender de forma intermitente Modo de flotaci n Totalmente cargada 4 barras encendidas Porcentaje de carga Voltaje de la bater a Pantalla LCD Carga 50 1 717V celda 1...

Page 9: ...las bater as baja a una advertencia de bajo voltaje o se programa la funci n 12 Informaci n de modo de operaci n Indica que la unidad est conectada a la red Indica que la carga es suministrada por la...

Page 10: ...V 13 7V Selladas plomo 14 4V 13 6V Gel euro 14 4V 13 8V Abiertas plomo 14 8V 13 8V Calcio 15 1V 13 6V De sulfataci n 15 5V por 4 horas Litio Cuando el voltaje de la bater a alcance 14 7V la UPS cierra...

Page 11: ...o Permanecer en la pantalla Si se selecciona la pantalla permanecer en la ltima seleccionada por el usuario 20 Control de luz trasera Luz trasera encendida prede terminado Luz trasera apagada 22 Beep...

Page 12: ...96 Bajo voltaje de bater a Cuando el voltaje de la bater a llega al punto configurado el contacto seco cambia de NC a NO Esta configuraci n no puede ser m s baja que el bajo voltaje de corte de la ba...

Page 13: ...re temperatura del inversor 07 Sobre carga del inversor 88 Fase de transformaci n reversa 89 La frecuencia est fuera de rango 97 El inversor falla la comunicaci n con MPPT C digo de advertencia Evento...

Page 14: ...gundos de carga continua Protecci n de cortocircuito Protecci n de software Eficiencia a potencia nominal 93 Eficiencia pico del inversor 95 Factor de potencia 0 9 1 Mono en l nea Rango de voltaje de...

Page 15: ...o de voltaje de bater a Advertencia por bajo voltaje DC Corte por bajo voltaje DC 12V 10Vdc 16Vdc 0 3Vdc 2 24V 4 48V 12V 10 5Vdc 0 3Vdc 2 24V 4 48V 12V 10Vdc 0 3Vdc 2 24V 4 48V Otros Rango de temperat...

Page 16: ...re doing any maintenance or cleaning Turning off the unit will not reduce this risk WARNING Only qualified personal can install this inverter with the battery Never charge a frozen battery For optimal...

Page 17: ...n case that the load is powered by electric supply the electric supply must pass the input protections of the charger inverter Teca Litio and to filter the signal before supplying energy in order to e...

Page 18: ...ve 8 Output inverter protection 9 Load input protection 10 Input Output For a proper ventilation an adequate space in the installation and cabling is required for it to improve the air flow in the sys...

Page 19: ...firm the selection on setting mode con Function description Input source information Indicates the AC input Indicates input voltage input frequency PV voltage battery voltage and charging current Prog...

Page 20: ...t line will flash in turns Floating mode Totally charged 4 bars will be on Load percentage Battery voltage LCD Display Load 50 1 717V cell 1 717V cell 1 8V cell 1 8V cell 1 883V cell 1 883V cell 50 Lo...

Page 21: ...es drops to a low level warning voltage or the setting point in the program is 12 Operation mode information Indicates that the unit is connected to the grid Indicates that the load is supplied by the...

Page 22: ...1 14 1V 13 4V A G M 2 14 6V 13 7V Sealed lead acid 14 4V 13 6V Gel euro 14 4V 13 8V Open lead acid 14 8V 13 8V Calcium 15 1V 13 6V De sulphation 15 5V for 4 hours Lithium When the battery voltage is 1...

Page 23: ...acklight off 22 Beep when the primary energy source is interrupted Alarm on default Alarm off 25 Fault code record Record enabled Record disabled 26 Bulk charging voltage If selected User defined as 9...

Page 24: ...ncrease per click is 0 1V for 12V systems 2 24V 4 48V 96 Low battery voltage It appears when the battery voltage reaches to the setup point and the dry contact changes from NC to NO This setting canno...

Page 25: ...Inverter overtemperature 07 Overload of the inverter 88 Reversal transformer phase 89 Frequency is out of range 97 The inverter fails to connect to the MPPT controller Fault code Event Icon 02 Overtem...

Page 26: ...oads Load 200 10 fault output turns off after 1 5 seconds of continous loads Short circuit Breaker Rated efficiency 93 Peak efficiency 95 Power factor 0 9 1 Line mode Input voltage range Input voltage...

Page 27: ...24V 24V 24V 48V 48V Battery voltage range Low DC voltage warning Low DC voltage cut off 12V 10Vdc 16Vdc 0 3Vdc 2 24V 4 48V 12V 10 5Vdc 0 3Vdc 2 24V 4 48V 12V 10Vdc 0 3Vdc 2 24V 4 48V Others Operation...

Page 28: ...28 www intipv com MANUAL DE USUARIO INVERSOR TECA LITIO USER MANUAL INVERSOR TECA LITIO info intipv com www intipv com Barcelona Espa a...