LED CODE CHART

LED Reading

CAUSE

SOLUTION

E81

Transmission signal failure

•  Reset the RCD, restart all over again.
•  Place the control panel within 5 m (16 ft) of the 

control base unit.

•  Press and hold POWER button for 5 seconds to 

turn off  and charge the panel again.

•  If problem persists, contact Intex Service Center.

E90

No water fl ow

•  Turn off  and unplug the control unit.
•  Ensure the outlet cover grid is clean and free from 

obstructions.

•  Clean or replace the cartridge, see Maintenance 

and Storage section.

•  Ensure the in/outlet connections on the spa tub and 

fi lter pump are not blocked.

•  Keep the spa water properly sanitized to ensure a 

clean and unclogged fi lter cartridge.

•  If problem persists, contact Intex Service Center.

E94

Water temperature too low

•  If the ambient temperature is below 4°C (39°F), we 

recommend not to use the spa.

•  Turn off  and unplug the control unit, add some 

warm water to raise the spa water temperature 
above 5°C (41°F), then press the

 

 button to heat 

up the water to the desired temperature.

•  If problem persists, contact Intex Service center.

E95

Water temperature too high

•  Turn off  and unplug the control unit. When the water 

has cooled down, plug the RCD and restart all over 
again.

•  Turn the heater off , then press the fi lter and bubble 

buttons to lower the water temperature.

•  If problem persists, contact Intex Service Center.

E96

System Error

•  Turn off  and unplug the control unit. Plug the RCD 

and restart all over again.

•  If problem persists, contact Intex Service Center.

E97

Dry-fi re Protection

•  Contact Intex Service Center.

E99

Water temperature sensor broken •  Contact Intex Service Center.

END

After 72 hours of continuous 

heating operation, the pump will 

hibernate automatically. The rapid 

heating function is disabled.

•  Press the

 

 button to re-active the fi lter pump. 

BLANK

Control panel battery has no power 

or in “Power Saving Mode” waiting 

to be placed on the control base 

charging dock.

•  Press any button to reactivate the control panel.
•  Reset the RCD, restart all over again and charge 

the control panel again.

•  Make sure the surface between the back of the 

control panel and the control base charging dock is 
clean, dry and free of obstruction.

•  If problem persists, contact Intex Service Center.

Summary of Contents for PureSpa Greywood Deluxe SB-HWF20

Page 1: ...ehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilis es dans certains pays sous licence de Marca...

Page 2: ...9 18 2020 English Page 2 Warning 3 6 Parts 7 8 Set up 9 14 Operation 15 20 Minimize Heat Loss and Energy Consumption Advice 20 LED Code Chart 21 Maintenance and Chemicals 22 26 Storage 26 Troubleshoot...

Page 3: ...and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes It is recommended to seek medical advice before...

Page 4: ...lows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include an increase in...

Page 5: ...ter The spa must be setup on a level at and smooth surface that is capable of supporting the maximum load of the lled spa with four adult occupants weight 1136 kg 2500 lbs six adults 1592 kg 3500 lbs...

Page 6: ...pulmonary Resuscitation CPR and refresh this knowledge regularly This can make a life saving di erence in the event of an emergency Instruct all spa users including children what to do in case of an e...

Page 7: ...Page 7 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary...

Page 8: ...87 11687 1 11687 11687 10 SPA DRAIN PLUG 1 11995 11995 1 11995 11995 11 SPA DRAIN VALVE ADAPTOR 1 13036 13036 1 13036 13036 12 FILTER CARTRIDGE HOUSING 1 11798 11798 1 11798 11798 13 FILTER CARTRIDGE...

Page 9: ...f the cord mounted RCD Make sure there is enough clearance around the spa for full access to the spa equipment for maintenance and or service The area shall facilitate draining purposes during long te...

Page 10: ...Check with a quali ed contractor or a structural engineer to verify this requirement Make sure the oor is water resistant and non slip surface Do not install the spa on carpet or other materials that...

Page 11: ...lower in ation outlet Pull out the latch to open the cover insert the hose adaptor 24 with hose and reattach the latch to the hose adaptor to secure it in place see drawing 3 3 Unscrew the air valve c...

Page 12: ...core from the valve base Insert the replacement core and tighten with the wrench Make sure the core is securely tightened see drawing 7 In ate the Spa Cover Air Bladder 1 Open the in ation valve and...

Page 13: ...orrect air pressure is restored Air expands in the midday heat Air pressure release valve kicks in and releases excess air In ation of spa in the morning IMPORTANT De ation For Spa Tub Wall 1 Unscrew...

Page 14: ...over over the spa tub and make sure the spa cover buckles are locked using the key provided after pulling the buckled straps tight IMPORTANT Inspect the spa cover regularly for leak premature wear and...

Page 15: ...n o the lter pump and the LED display shows the spa water temperature If you have selected too many hours keep pressing to repeat the cycle Once the operating time is set the LED display will stop ash...

Page 16: ...simply set the HST time back to 000 To readjust the preset hours press the HST button twice and adjust the hours with and buttons Example 1 It is 9 00pm Monday evening and you would like the spa to b...

Page 17: ...on your spa and program a schedule for future use remotely even when not at home from your mobile device System and WiFi Router Requirement The Spa control base hardware communicates over a 2 4GHz net...

Page 18: ...FLINE with a red dot at the front WiFi connection failed ONLINE with a green dot at the front mobile device and spa control panel paired up successfully to the same WiFi router signal ONLINE with a bl...

Page 19: ...0 104 012H 005H Turn the heater on some time into the future to a set temperature and set a run time at which point the heater will turn itself o The heater will start after 12 hours and continuously...

Page 20: ...tted tightly as per manufacturer s instructions to maximize insulation It shall be recommended that the cover when not in use should be kept o the ground to retain its cleanliness particularly the sur...

Page 21: ...utton to heat up the water to the desired temperature If problem persists contact Intex Service center E95 Water temperature too high Turn o and unplug the control unit When the water has cooled down...

Page 22: ...onto the spa tub wall 2 Change the spa water every 2 weeks See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper water chemistry Spa damage resulting f...

Page 23: ...is acceptable as also recommended by the U S Environmental Protection Agency and the Center for Disease Control Do not use cyanuric acid h Temporary exceeding due to manual dosage and low water volume...

Page 24: ...r cloudy water condition If SI 0 Corrosive to metals or eye skin irritating condition The SI is considered satisfactory if the value is within 0 3 to 0 3 range Zero being perfect WARNING Handle all ch...

Page 25: ...tion on how to drain the spa While empty remove the cartridge housing from inside of the spa tub wall clean and or replace the lter cartridge Use a sponge and mild soap solution to wipe away any soil...

Page 26: ...use for the purpose described in this manual Keep the in ation hose away from water or small objects when the de ation function is activated to avoid damage to the blower motor 4 Make sure all the spa...

Page 27: ...s too hot Turn o and unplug the spa Let it cool down and restart all over again If problem persists contact Intex Service Center FILTRATION PUMP NOT WORKING Dirty lter cartridge Filtration inlet and o...

Page 28: ...let O ring is in place clean and not damaged SPA IS TOO NOISY IN FILTRATION MODE ONLY Control base components not securely attached Control base ground not level and rm Spa lter motor failed Ensure co...

Page 29: ...trol panel are connected to the same WiFi router signal Wrong WiFi password Ensure correct WiFi router password See WiFi pairing binding section The setup spa location is too far from your WiFi router...

Page 30: ...l and your mobile device can access and browse the internet from the location where the spa is setup If you cannot move your spa then you need to move your WiFi router or add a repeater signal booster...

Page 31: ...follow below steps to disassemble it IMPORTANT You must drain out any remaining water inside the piping system of the control base before replacing any parts Tools required One adjustable wrench and...

Page 32: ...he provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this warranty and other legal rights in your count...